{"id":991,"date":"2021-05-07T06:05:06","date_gmt":"2021-05-07T06:05:06","guid":{"rendered":"https:\/\/www.wolunelectric.com\/?post_type=product&#038;p=991"},"modified":"2026-05-12T10:51:39","modified_gmt":"2026-05-12T02:51:39","slug":"xrnp-high-voltage-fuse","status":"publish","type":"product","link":"https:\/\/www.wolunelectric.com\/vi\/product\/xrnp-high-voltage-fuse\/","title":{"rendered":"XRNP High Voltage Fuse"},"content":{"rendered":"<div data-page-id=\"EYkFd9XFLonJISxlCeecVr9xnUD\" data-lark-html-role=\"root\" data-docx-has-block-data=\"false\">\n<h2 class=\"heading-2 ace-line old-record-id-Z4jPfoY4VdRLV7cCc4zcKk1TnMb\">Product Overview<\/h2>\n<div class=\"ace-line ace-line old-record-id-RHgQfWW7fdPVAXcilGdcLnvin1g\">The XRNP series high voltage fuse is a professional current-limiting protective component specifically designed for voltage transformer (PT) protection in 3.6kV-40.5kV AC power systems (50Hz). It is mainly used for short-circuit and overload protection of voltage transformers, as well as protection of related auxiliary equipment in PT circuits. With its excellent current-limiting performance, high breaking capacity, and precise fusing characteristics, it can quickly cut off fault currents in milliseconds, effectively protecting PTs from damage caused by short-circuit currents and overloads, and ensuring the safe and continuous operation of the entire power measurement and control system. It is widely applied in power substations, industrial and mining enterprises, and other scenarios with high-voltage PT equipment.<\/div>\n<\/div>\n<div><\/div>\n<div>\n<div data-page-id=\"EYkFd9XFLonJISxlCeecVr9xnUD\" data-lark-html-role=\"root\" data-docx-has-block-data=\"false\">\n<h2 class=\"heading-2 ace-line old-record-id-SDHIfyplLdMpm0cd3JFcanE7ncc\">Core Features<\/h2>\n<ul class=\"list-bullet1\">\n<li class=\"ace-line ace-line old-record-id-BZUIfP7D8dkmkXcrHc6cRaGenwd\" data-list=\"bullet\">\n<div><strong>Professional PT Protection Design<\/strong>: Specifically developed for voltage transformer circuits, it features low power consumption and low temperature rise, with a fast response time to quickly isolate faults and prevent PT burnout.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-J5nVfd3wmdnkQLcWcQ0cjKKyn7f\" data-list=\"bullet\">\n<div><strong>High Breaking Capacity<\/strong>: Adopts advanced current-limiting structure with a rated breaking capacity of 50kA, which can quickly limit fault currents to a safe range before the peak value, minimizing the impact of short-circuit currents on PTs and power grids.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-JUFffCiJ3dRfhtcRSavc2rLxn5b\" data-list=\"bullet\">\n<div><strong>Precise Fusing Characteristics<\/strong>: Equipped with a high-sensitivity melt, calibrated strictly according to PT operating parameters, ensuring accurate response to overload and short-circuit faults. The fusing characteristic error is less than \u00b110% for reliable protection.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-CTRKfLNNjdQiWEceJ2Oca2XJnnf\" data-list=\"bullet\">\n<div><strong>Durable Ceramic Structure<\/strong>: The outer tube is made of high-strength alumina ceramic, which has excellent high-temperature resistance, pressure resistance, and insulation performance. It can withstand the high temperature and pressure generated during arc extinction, ensuring long service life.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-KTxNfZJDTdXU4kcwPiacSpJKnah\" data-list=\"bullet\">\n<div><strong>Easy Installation &amp; Wide Compatibility<\/strong>: Designed for indoor cabinet installation, with compact structure and standardized size, suitable for most medium-voltage switchgears and PT cabinets. Factory-calibrated, no additional adjustment is required during installation.<\/div>\n<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h2><strong>Model&amp;Meaning<\/strong><\/h2>\n<h4><strong><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-992\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP-HIGH-VOLTAGE-FUSE.png\" alt=\"XRNP High Voltage Fuse\" width=\"1060\" height=\"392\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP-HIGH-VOLTAGE-FUSE.png 1060w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP-HIGH-VOLTAGE-FUSE-300x111.png 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP-HIGH-VOLTAGE-FUSE-1024x379.png 1024w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP-HIGH-VOLTAGE-FUSE-768x284.png 768w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP-HIGH-VOLTAGE-FUSE-600x222.png 600w\" sizes=\"(max-width: 1060px) 100vw, 1060px\" \/><\/strong><\/h4>\n<p>&nbsp;<\/p>\n<h2><strong>Technical Specification<\/strong><\/h2>\n<p>&nbsp;<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"1\" cellpadding=\"5\" bgcolor=\"#dcdcdc\">\n<tbody>\n<tr bgcolor=\"#f0f9ff\">\n<td align=\"center\">Models<\/td>\n<td rowspan=\"2\" align=\"center\">Ratedvoltage (KV)<\/td>\n<td rowspan=\"2\" align=\"center\">Rated current of the fuse links(A)<\/td>\n<td rowspan=\"2\" align=\"center\">Rated breakingcurrent (KA)<\/td>\n<td colspan=\"2\" align=\"center\">Dimensions (mm)<\/td>\n<td rowspan=\"2\" align=\"center\">Weight (Kg)<\/td>\n<\/tr>\n<tr bgcolor=\"#f0f9ff\">\n<td align=\"center\">Department<\/td>\n<td align=\"center\">Fig.<\/td>\n<td align=\"center\">L<\/td>\n<\/tr>\n<tr bgcolor=\"#ffffff\">\n<td>XRNP1<\/td>\n<td>3.6<\/td>\n<td>0.5, 1, 2, 3.15, 6.3<\/td>\n<td>50<\/td>\n<td rowspan=\"5\">Figure 1<\/td>\n<td>142<\/td>\n<td>0.19<\/td>\n<\/tr>\n<tr bgcolor=\"#ffffff\">\n<td>XRNP1<\/td>\n<td>7.2<\/td>\n<td>0.5, 1, 2, 3.15, 6.3<\/td>\n<td>50<\/td>\n<td>142(195)<\/td>\n<td>0.19(0.22)<\/td>\n<\/tr>\n<tr bgcolor=\"#ffffff\">\n<td>XRNP1<\/td>\n<td>12<\/td>\n<td>0.5, 1, 2, 3.15<\/td>\n<td>40<\/td>\n<td>195<\/td>\n<td>0.22<\/td>\n<\/tr>\n<tr bgcolor=\"#ffffff\">\n<td>XRNP1<\/td>\n<td>24<\/td>\n<td>0.5, 1, 2, 3.15<\/td>\n<td>40<\/td>\n<td>355<\/td>\n<td>0.43<\/td>\n<\/tr>\n<tr bgcolor=\"#ffffff\">\n<td>XRNP1<\/td>\n<td>40.5<\/td>\n<td>0.5, 1, 2, 3.15<\/td>\n<td>50<\/td>\n<td>465<\/td>\n<td>0.55<\/td>\n<\/tr>\n<tr bgcolor=\"#ffffff\">\n<td>XRNP2<\/td>\n<td>12<\/td>\n<td>0.5, 1, 2, 3.15<\/td>\n<td>50<\/td>\n<td colspan=\"2\">Figure 2<\/td>\n<td>1.12<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h5><\/h5>\n<h2><strong>Outline&amp;Drawing<\/strong><\/h2>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-993\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP1-12KV-H.V.-Fuse-1.jpg\" alt=\"\" width=\"1154\" height=\"611\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP1-12KV-H.V.-Fuse-1.jpg 1154w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP1-12KV-H.V.-Fuse-1-300x159.jpg 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP1-12KV-H.V.-Fuse-1-1024x542.jpg 1024w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP1-12KV-H.V.-Fuse-1-768x407.jpg 768w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP1-12KV-H.V.-Fuse-1-600x318.jpg 600w\" sizes=\"(max-width: 1154px) 100vw, 1154px\" \/> <img decoding=\"async\" class=\"alignnone size-full wp-image-996\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP2-12KV-H.V.-FUSE-1-1-1.jpg\" alt=\"\" width=\"1168\" height=\"662\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP2-12KV-H.V.-FUSE-1-1-1.jpg 1168w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP2-12KV-H.V.-FUSE-1-1-1-300x170.jpg 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP2-12KV-H.V.-FUSE-1-1-1-1024x580.jpg 1024w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP2-12KV-H.V.-FUSE-1-1-1-768x435.jpg 768w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/XRNP2-12KV-H.V.-FUSE-1-1-1-600x340.jpg 600w\" sizes=\"(max-width: 1168px) 100vw, 1168px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<div data-page-id=\"EYkFd9XFLonJISxlCeecVr9xnUD\" data-lark-html-role=\"root\" data-docx-has-block-data=\"false\">\n<div class=\"ace-line ace-line old-record-id-PqZQfc6LYdsYZCctFS3cRJlMnbc\">Specialized XRNP current-limiting fuse, dedicated to short-circuit and overload protection for 3.6kV-40.5kV voltage transformers, ensuring safe and stable operation of PT systems.<\/div>\n<\/div>","protected":false},"featured_media":997,"template":"","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"XRNP High Voltage Fuse | 3.6kV-40.5kV Voltage Transformer Short-Circuit & Overload Protection","_seopress_titles_desc":"High-performance XRNP high voltage fuse for voltage transformer protection, 3.6kV-40.5kV rated voltage, 0.2A-10A rated current, IEC\/GB compliant. Current-limiting design, high breaking capacity, ideal for PT circuits.","_seopress_robots_index":""},"product_brand":[],"product_cat":[47],"product_tag":[],"class_list":{"0":"post-991","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-fuse-tube","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/product\/991","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/media\/997"}],"wp:attachment":[{"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/media?parent=991"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/product_brand?post=991"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/product_cat?post=991"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/product_tag?post=991"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}