{"id":920,"date":"2021-04-29T07:39:10","date_gmt":"2021-04-29T07:39:10","guid":{"rendered":"https:\/\/www.wolunelectric.com\/?post_type=product&#038;p=920"},"modified":"2026-05-20T11:02:36","modified_gmt":"2026-05-20T03:02:36","slug":"gn-72-dc-disconnector-electric-dust-removal-single-pole-high-voltage-isolation-switch-gn3-72-2-1s-72kv-2a","status":"publish","type":"product","link":"https:\/\/www.wolunelectric.com\/vi\/product\/gn-72-dc-disconnector-electric-dust-removal-single-pole-high-voltage-isolation-switch-gn3-72-2-1s-72kv-2a\/","title":{"rendered":"GN-72 DC disconnector, electric dust removal single pole high voltage isolation switch GN3-72\/2-1S 72KV 2A"},"content":{"rendered":"<div class=\"no-scrollbar flex min-h-36 flex-nowrap gap-0.5 overflow-auto sm:gap-1 sm:overflow-hidden xl:min-h-44 mt-1 mb-5 not-first:mt-4\">\n<div class=\"border-token-border-default relative w-32 shrink-0 overflow-hidden rounded-xl border-[0.5px] md:shrink max-h-64 sm:w-[calc((100%-0.5rem)\/3)] rounded-e-xl\">\n<div class=\"group\/search-image @container\/search-image relative rounded-[inherit] h-full w-full\">\n<div class=\"pointer-events-none absolute inset-x-2 bottom-2 z-10 flex max-w-[calc(100%-1rem)] flex-wrap items-end justify-end gap-1.5\">\n<div class=\"shrink-0\">\n<div class=\"flex items-center gap-1 rounded-full px-2 py-1.5 text-white backdrop-blur-md backdrop-brightness-75\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p data-start=\"460\" data-end=\"690\">The GN-72 series DC isolating switch adopts a <strong data-start=\"506\" data-end=\"560\">left-hand or right-hand rotary operating mechanism<\/strong> and is installed between the electrostatic precipitator insulating support and the silicon rectifier transformer output terminal.<\/p>\n<p data-start=\"692\" data-end=\"719\">Its primary function is to:<\/p>\n<ul data-start=\"720\" data-end=\"891\">\n<li data-section-id=\"tjesbl\" data-start=\"720\" data-end=\"758\">isolate the high-voltage DC circuit,<\/li>\n<li data-section-id=\"pgxdg2\" data-start=\"759\" data-end=\"785\">ensure safe maintenance,<\/li>\n<li data-section-id=\"1lad9qx\" data-start=\"786\" data-end=\"834\">provide grounding capability during servicing,<\/li>\n<li data-section-id=\"jmyv5l\" data-start=\"835\" data-end=\"891\">improve personnel safety during inspection and repair.<\/li>\n<\/ul>\n<p data-start=\"893\" data-end=\"922\">The switch is widely used in:<\/p>\n<ul data-start=\"923\" data-end=\"1098\">\n<li data-section-id=\"14r1yq2\" data-start=\"923\" data-end=\"958\">Electrostatic precipitators (ESP)<\/li>\n<li data-section-id=\"fadwse\" data-start=\"959\" data-end=\"984\">Dust collection systems<\/li>\n<li data-section-id=\"o22h4u\" data-start=\"985\" data-end=\"1032\">Industrial environmental protection equipment<\/li>\n<li data-section-id=\"zd7umg\" data-start=\"1033\" data-end=\"1055\">Thermal power plants<\/li>\n<li data-section-id=\"ys26o8\" data-start=\"1056\" data-end=\"1071\">Cement plants<\/li>\n<li data-section-id=\"uhow4u\" data-start=\"1072\" data-end=\"1098\">Metallurgical industries<\/li>\n<\/ul>\n<p data-start=\"1100\" data-end=\"1137\">\n<h2 data-section-id=\"7jig15\" data-start=\"1139\" data-end=\"1155\">Main Features<\/h2>\n<ul data-start=\"1157\" data-end=\"1469\">\n<li data-section-id=\"lrjam7\" data-start=\"1157\" data-end=\"1193\">Single-pole DC isolation structure<\/li>\n<li data-section-id=\"1rdnx65\" data-start=\"1194\" data-end=\"1223\">Rated DC voltage up to 72kV<\/li>\n<li data-section-id=\"czx11q\" data-start=\"1224\" data-end=\"1253\">Compact and reliable design<\/li>\n<li data-section-id=\"1fzim5q\" data-start=\"1254\" data-end=\"1282\">Rotary handwheel operation<\/li>\n<li data-section-id=\"47yuq6\" data-start=\"1283\" data-end=\"1312\">High insulation performance<\/li>\n<li data-section-id=\"u571kf\" data-start=\"1313\" data-end=\"1347\">Suitable for indoor installation<\/li>\n<li data-section-id=\"3ru7ts\" data-start=\"1348\" data-end=\"1391\">Stable conductivity and long service life<\/li>\n<li data-section-id=\"1adx8oa\" data-start=\"1392\" data-end=\"1424\">Maintenance-friendly structure<\/li>\n<li data-section-id=\"17pbyqd\" data-start=\"1425\" data-end=\"1469\">Optional left-hand or right-hand operation<\/li>\n<\/ul>\n<h2 data-section-id=\"1cgu054\" data-start=\"1471\" data-end=\"1498\">Technical Specifications<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" style=\"height: 537px;\" width=\"717\" data-start=\"1500\" data-end=\"1867\">\n<thead data-start=\"1500\" data-end=\"1524\">\n<tr data-start=\"1500\" data-end=\"1524\">\n<th class=\"last:pe-10\" data-start=\"1500\" data-end=\"1507\" data-col-size=\"sm\">Item<\/th>\n<th class=\"last:pe-10\" data-start=\"1507\" data-end=\"1524\" data-col-size=\"sm\">Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1535\" data-end=\"1867\">\n<tr data-start=\"1535\" data-end=\"1558\">\n<td data-start=\"1535\" data-end=\"1543\" data-col-size=\"sm\">Model<\/td>\n<td data-start=\"1543\" data-end=\"1558\" data-col-size=\"sm\">GN3-72\/2-1S<\/td>\n<\/tr>\n<tr data-start=\"1559\" data-end=\"1586\">\n<td data-start=\"1559\" data-end=\"1578\" data-col-size=\"sm\">Rated DC Voltage<\/td>\n<td data-start=\"1578\" data-end=\"1586\" data-col-size=\"sm\">72kV<\/td>\n<\/tr>\n<tr data-start=\"1587\" data-end=\"1612\">\n<td data-start=\"1587\" data-end=\"1606\" data-col-size=\"sm\">Rated DC Current<\/td>\n<td data-start=\"1606\" data-end=\"1612\" data-col-size=\"sm\">2A<\/td>\n<\/tr>\n<tr data-start=\"1613\" data-end=\"1651\">\n<td data-start=\"1613\" data-end=\"1620\" data-col-size=\"sm\">Type<\/td>\n<td data-start=\"1620\" data-end=\"1651\" data-col-size=\"sm\">Single Pole DC Disconnector<\/td>\n<\/tr>\n<tr data-start=\"1652\" data-end=\"1677\">\n<td data-start=\"1652\" data-end=\"1667\" data-col-size=\"sm\">Installation<\/td>\n<td data-start=\"1667\" data-end=\"1677\" data-col-size=\"sm\">Indoor<\/td>\n<\/tr>\n<tr data-start=\"1678\" data-end=\"1724\">\n<td data-start=\"1678\" data-end=\"1697\" data-col-size=\"sm\">Operation Method<\/td>\n<td data-start=\"1697\" data-end=\"1724\" data-col-size=\"sm\">Manual rotary operation<\/td>\n<\/tr>\n<tr data-start=\"1725\" data-end=\"1776\">\n<td data-start=\"1725\" data-end=\"1739\" data-col-size=\"sm\">Application<\/td>\n<td data-start=\"1739\" data-end=\"1776\" data-col-size=\"sm\">Electrostatic precipitator system<\/td>\n<\/tr>\n<tr data-start=\"1777\" data-end=\"1816\">\n<td data-start=\"1777\" data-end=\"1799\" data-col-size=\"sm\">Ambient Temperature<\/td>\n<td data-start=\"1799\" data-end=\"1816\" data-col-size=\"sm\">-20\u00b0C ~ +60\u00b0C<\/td>\n<\/tr>\n<tr data-start=\"1817\" data-end=\"1845\">\n<td data-start=\"1817\" data-end=\"1837\" data-col-size=\"sm\">Relative Humidity<\/td>\n<td data-start=\"1837\" data-end=\"1845\" data-col-size=\"sm\">\u226495%<\/td>\n<\/tr>\n<tr data-start=\"1846\" data-end=\"1867\">\n<td data-start=\"1846\" data-end=\"1857\" data-col-size=\"sm\">Altitude<\/td>\n<td data-start=\"1857\" data-end=\"1867\" data-col-size=\"sm\">\u22642000m<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"1869\" data-end=\"1906\">\n<h2 data-section-id=\"2toy6x\" data-start=\"1908\" data-end=\"1934\">Installation Conditions<\/h2>\n<p data-start=\"1936\" data-end=\"2002\">The installation environment should meet the following conditions:<\/p>\n<ul data-start=\"2004\" data-end=\"2201\">\n<li data-section-id=\"c2vudv\" data-start=\"2004\" data-end=\"2031\">No severe conductive dust<\/li>\n<li data-section-id=\"ue6nf\" data-start=\"2032\" data-end=\"2071\">No corrosive gases or metal particles<\/li>\n<li data-section-id=\"1mt2u08\" data-start=\"2072\" data-end=\"2093\">No strong vibration<\/li>\n<li data-section-id=\"16cmcea\" data-start=\"2094\" data-end=\"2132\">Flat and secure installation surface<\/li>\n<li data-section-id=\"b3ejjf\" data-start=\"2133\" data-end=\"2201\">Minimum safety clearance above 300mm around high-voltage terminals<\/li>\n<\/ul>\n<p data-start=\"2203\" data-end=\"2288\">If used outdoors, the switch should be installed inside a protective metal enclosure.<\/p>\n<p data-start=\"2290\" data-end=\"2327\">\n<h2 data-section-id=\"dysc5y\" data-start=\"2329\" data-end=\"2350\">Product Advantages<\/h2>\n<h3 data-section-id=\"1hfuwrw\" data-start=\"2352\" data-end=\"2379\">High Safety Performance<\/h3>\n<p data-start=\"2380\" data-end=\"2483\">Designed specifically for safe isolation and grounding of ESP high-voltage circuits during maintenance.<\/p>\n<h3 data-section-id=\"193yiy6\" data-start=\"2485\" data-end=\"2508\">Reliable Insulation<\/h3>\n<p data-start=\"2509\" data-end=\"2599\">Suitable for harsh industrial dust-removal environments with stable insulation capability.<\/p>\n<h3 data-section-id=\"1jlur85\" data-start=\"2601\" data-end=\"2621\">Easy Maintenance<\/h3>\n<p data-start=\"2622\" data-end=\"2693\">Simple structure allows convenient inspection and periodic lubrication.<\/p>\n<h3 data-section-id=\"cvgblj\" data-start=\"2695\" data-end=\"2716\">Long Service Life<\/h3>\n<p data-start=\"2717\" data-end=\"2803\">Mechanical structure ensures reliable long-term operation under industrial conditions.<\/p>\n<h2 data-section-id=\"164os46\" data-start=\"2805\" data-end=\"2828\">Typical Applications<\/h2>\n<ul data-start=\"2830\" data-end=\"2992\">\n<li data-section-id=\"12r9tvx\" data-start=\"2830\" data-end=\"2859\">Electrostatic precipitators<\/li>\n<li data-section-id=\"wojvv5\" data-start=\"2860\" data-end=\"2894\">Flue gas dust collection systems<\/li>\n<li data-section-id=\"1rqji79\" data-start=\"2895\" data-end=\"2929\">Environmental protection systems<\/li>\n<li data-section-id=\"fhkr11\" data-start=\"2930\" data-end=\"2956\">HV DC isolation circuits<\/li>\n<li data-section-id=\"c1f6n1\" data-start=\"2957\" data-end=\"2992\">Industrial dust removal equipment<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>GN3-72\/2-1S is a 72kV 2A single-pole high voltage DC disconnector designed for electrostatic precipitator and electric dust removal systems.<\/p>\n<p>It provides reliable isolation, grounding, and maintenance safety for HV DC circuits.<\/p>","protected":false},"featured_media":925,"template":"","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"GN3-72\/2-1S 72kV 2A DC Disconnector | High Voltage Isolation Switch for ESP","_seopress_titles_desc":"GN3-72\/2-1S 72kV 2A DC disconnector for electrostatic precipitator systems. Reliable high voltage isolation switch for electric dust removal and industrial HV DC applications.","_seopress_robots_index":""},"product_brand":[],"product_cat":[46],"product_tag":[],"class_list":{"0":"post-920","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-high-voltage-disconnect-switch","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/product\/920","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/media\/925"}],"wp:attachment":[{"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/media?parent=920"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/product_brand?post=920"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/product_cat?post=920"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/vi\/wp-json\/wp\/v2\/product_tag?post=920"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}