{"id":907,"date":"2021-04-28T08:07:00","date_gmt":"2021-04-28T08:07:00","guid":{"rendered":"https:\/\/www.wolunelectric.com\/?post_type=product&#038;p=907"},"modified":"2026-05-13T15:00:37","modified_gmt":"2026-05-13T07:00:37","slug":"sn10-10kv-indoor-less-oil-circuit-breaker","status":"publish","type":"product","link":"https:\/\/www.wolunelectric.com\/th\/product\/sn10-10kv-indoor-less-oil-circuit-breaker\/","title":{"rendered":"SN10-10 10kV Indoor Less Oil Circuit Breaker"},"content":{"rendered":"<p>&nbsp;<\/p>\n<h2><strong>General Introduction<\/strong><\/h2>\n<div class=\"woocommerce-tabs\">\n<div id=\"tab-description\" class=\"panel entry-content\">\n<p>SN10-10 series 10kV Indoor Less Oil Circuit Breaker is a traditional type medium voltage oil circuit breaker. It takes transformer oil as the arc quenching and insulating medium, with simple mechanical structure, stable breaking performance and high cost performance.<br \/>\nThis circuit breaker is mainly designed for 10kV indoor power distribution systems, suitable for frequent closing and opening operation, as well as overload and short-circuit fault protection for transformers, power lines and electrical equipment. It is widely adopted in old substation renovation, industrial plants, mining enterprises and conventional power grid projects.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Working Conditons<\/strong><\/h2>\n<p>Ambient temperature: not higher than +40 \u00b0C, not less than -15\u00b0C<\/p>\n<p>Altitude: not exceed 1000m.<\/p>\n<p>Relative humidity: daily average of not more than 95%, month average of not more than 90%.<\/p>\n<p>Earthquake intensity: not more than ten.<\/p>\n<p>No fire, explosion hazard, serious filthy, chemical corrosion, as well as places of intense vibration.<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<h2>Key Features<\/h2>\n<p>Mature less oil arc extinguishing technology, stable and reliable operation<\/p>\n<p>Simple mechanical structure, easy installation, inspection and maintenance<\/p>\n<p>Multiple rated current and breaking current specifications for selection<\/p>\n<p>Strong overload and short-circuit breaking capability<\/p>\n<p>Suitable for indoor fixed switch cabinet installation<\/p>\n<p>Low failure rate, long service life and competitive price<\/p>\n<div id=\"tab-description\" class=\"panel entry-content\">\n<h4><\/h4>\n<h2>Technical Specifications<\/h2>\n<ul>\n<li>Model: SN10-10<\/li>\n<li>Rated Voltage: 10kV<\/li>\n<li>Rated Frequency: 50Hz<\/li>\n<li>Rated Current: 630A, 1000A, 1250A<\/li>\n<li>Rated Short-circuit Breaking Current: 16kA, 20kA, 31.5kA<\/li>\n<li>Installation: Indoor floor \/ cabinet mounted<\/li>\n<li>Arc Quenching Medium: Transformer Less Oil<\/li>\n<li>Operating Mechanism: Electromagnetic type \/ Spring type<\/li>\n<li>Ambient Temperature: -20\u2103 ~ +40\u2103<\/li>\n<li>Applicable Altitude: \u22641000m<\/li>\n<\/ul>\n<table>\n<tbody>\n<tr>\n<td width=\"144\"><strong>NO<\/strong><\/td>\n<td width=\"144\"><strong>Item<\/strong><\/td>\n<td width=\"144\"><strong>Units<\/strong><\/td>\n<td width=\"144\"><strong>parameters<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"144\">1<\/td>\n<td width=\"144\">Rated voltage<\/td>\n<td width=\"144\">KV<\/td>\n<td width=\"144\">12<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">2<\/td>\n<td width=\"144\">Rated Frequency<\/td>\n<td width=\"144\">HZ<\/td>\n<td width=\"144\">50<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">3<\/td>\n<td width=\"144\">Rated Current<\/td>\n<td width=\"144\">A<\/td>\n<td width=\"144\">630.<\/p>\n<p>1250<\/p>\n<p>1600<\/p>\n<p>2000<\/p>\n<p>3150<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">4<\/td>\n<td width=\"144\">Rated short-circuit breaking current<\/td>\n<td width=\"144\">KA<\/td>\n<td width=\"144\">20 25 31.5<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">5<\/td>\n<td width=\"144\">Rated short-circuit closing current (peak)<\/td>\n<td width=\"144\">KA<\/td>\n<td width=\"144\">50 63 80<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">6<\/td>\n<td width=\"144\">Rated short-circuit duration<\/td>\n<td width=\"144\">S<\/td>\n<td width=\"144\">4<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">7<\/td>\n<td width=\"144\">Rated short-circuit breaking current breaking number<\/td>\n<td width=\"144\">nos<\/td>\n<td width=\"144\">50s<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">8<\/td>\n<td width=\"144\">Rated operating sequence<\/td>\n<td width=\"144\"><\/td>\n<td width=\"144\">0-0.3s-CO-180s-CO<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">9<\/td>\n<td width=\"144\">Rated lightning impulse withstandvoltage<\/td>\n<td width=\"144\">kv<\/td>\n<td width=\"144\">125<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">10<\/td>\n<td width=\"144\">1min power frequency withstand voltage<\/td>\n<td width=\"144\">KV<\/td>\n<td width=\"144\">65<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">11<\/td>\n<td width=\"144\">Closing time<\/td>\n<td width=\"144\">ms<\/td>\n<td width=\"144\">\u2264 70<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">12<\/td>\n<td width=\"144\">opening time<\/td>\n<td width=\"144\">ms<\/td>\n<td width=\"144\">\u2264 50<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">13<\/td>\n<td width=\"144\">Mechanical life<\/td>\n<td width=\"144\">Times<\/td>\n<td width=\"144\">20000<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">14<\/td>\n<td width=\"144\">Rated Storage and operation voltage<\/td>\n<td width=\"144\">V<\/td>\n<td width=\"144\">AC DC 220\/110<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">15<\/td>\n<td width=\"144\">Breaking life<\/td>\n<td width=\"144\">ms<\/td>\n<td width=\"144\">\u2264 80<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">16<\/td>\n<td width=\"144\">Storage life<\/td>\n<td width=\"144\">s<\/td>\n<td width=\"144\">\u2264 10<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Adjust the parameters of mechanical properties:<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"144\">No<\/td>\n<td width=\"144\">Item<\/td>\n<td width=\"144\">Unit<\/td>\n<td width=\"144\">Parameters<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">1<\/td>\n<td width=\"144\">Contact distance<\/td>\n<td width=\"144\">mm<\/td>\n<td width=\"144\">14\u00b11<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">2<\/td>\n<td width=\"144\">Contact Over-travel<\/td>\n<td width=\"144\">mm<\/td>\n<td width=\"144\">3.5\u00b11<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">3<\/td>\n<td width=\"144\">Closing speed<\/td>\n<td width=\"144\">m\/s<\/td>\n<td width=\"144\">1.0\u00b10.2<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">4<\/td>\n<td width=\"144\">Opening speed<\/td>\n<td width=\"144\">m\/s<\/td>\n<td width=\"144\">1.3\u00b10.2<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">5<\/td>\n<td width=\"144\">Contact closing spring time<\/td>\n<td width=\"144\">ms<\/td>\n<td width=\"144\">\u22642<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">6<\/td>\n<td width=\"144\">Rated contact pressure<\/td>\n<td width=\"144\">N<\/td>\n<td width=\"144\">20KA(2400\u00b1200) 25KA (2400\u00b1200) 31.5KA(3100\u00b1200)<\/td>\n<\/tr>\n<tr>\n<td width=\"144\">7<\/td>\n<td width=\"144\">Three phase closing opening asynchrony<\/td>\n<td width=\"144\">ms<\/td>\n<td width=\"144\">\u22642<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h2>Application<\/h2>\n<div>\n<p>It is commonly used in 10kV indoor substations, distribution rooms, industrial and mining enterprises, power plants and residential power supply systems.<\/p>\n<div><\/div>\n<p>Used for switching, overload protection and short-circuit protection of lines, transformers and other high-voltage equipment.<\/p>\n<\/div>\n<div><\/div>\n<h2>Our Services<\/h2>\n<div>We provide original SN10-10 less oil circuit breakers with complete specifications. Factory direct supply, fast delivery and professional technical support. Custom solution and OEM service are available for global customers.<\/div>\n<div>SN10-10 10kV Indoor Less Oil Circuit Breaker for MV Distribution System<\/div>\n<div><\/div>\n<h2>Outline Dimension<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-1816\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/SN10-10-outdoor-less-oil-circuit-breaker.jpg\" alt=\"sn10 10 outdoor less oil circuit breaker\" width=\"800\" height=\"782\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/SN10-10-outdoor-less-oil-circuit-breaker.jpg 800w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/SN10-10-outdoor-less-oil-circuit-breaker-300x293.jpg 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/SN10-10-outdoor-less-oil-circuit-breaker-768x751.jpg 768w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/SN10-10-outdoor-less-oil-circuit-breaker-600x587.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/> <img decoding=\"async\" class=\"alignnone size-full wp-image-1817\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/SN10-10-outdoor-less-oil-circuit-breaker-1.jpg\" alt=\"sn10 10 outdoor less oil circuit breaker 1\" width=\"798\" height=\"352\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/SN10-10-outdoor-less-oil-circuit-breaker-1.jpg 798w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/SN10-10-outdoor-less-oil-circuit-breaker-1-300x132.jpg 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/SN10-10-outdoor-less-oil-circuit-breaker-1-768x339.jpg 768w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/SN10-10-outdoor-less-oil-circuit-breaker-1-600x265.jpg 600w\" sizes=\"(max-width: 798px) 100vw, 798px\" \/><\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>SN10-10 10kV Indoor Less Oil Circuit Breaker is a classic medium voltage oil circuit breaker, adopting transformer oil for arc extinction and insulation. With mature structure, stable performance and economic cost, it is widely used in 10kV indoor switchgear and distribution substations.<\/p>","protected":false},"featured_media":908,"template":"","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"SN10-10 10kV Indoor Less Oil Circuit Breaker for MV Distribution System","_seopress_titles_desc":"SN10-10 indoor less oil circuit breaker is 10kV medium voltage oil circuit breaker, available in 630A 1000A 1250A, reliable for indoor substation cabinet installation and power distribution protection.","_seopress_robots_index":""},"product_brand":[],"product_cat":[44],"product_tag":[],"class_list":{"0":"post-907","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-vacuum-circuit-breaker","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/product\/907","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/media\/908"}],"wp:attachment":[{"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/media?parent=907"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/product_brand?post=907"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/product_cat?post=907"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/product_tag?post=907"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}