{"id":690,"date":"2021-04-25T07:25:12","date_gmt":"2021-04-25T07:25:12","guid":{"rendered":"https:\/\/www.wolunelectric.com\/?post_type=product&#038;p=690"},"modified":"2026-04-21T14:31:07","modified_gmt":"2026-04-21T06:31:07","slug":"hrw12-12-5-12kv-polymer-fuse-cutout-15kv-polymer-fuse-cutout","status":"publish","type":"product","link":"https:\/\/www.wolunelectric.com\/th\/product\/hrw12-12-5-12kv-polymer-fuse-cutout-15kv-polymer-fuse-cutout\/","title":{"rendered":"HRW12-12-5 12KV Polymer Fuse Cutout 15KV Polymer Fuse Cutout"},"content":{"rendered":"<h2>Product Overview\u200b<\/h2>\n<p>The HRW12-12-5 12kV\/15kV Polymer Fuse Cutout is a high-performance outdoor high-voltage protection device, specially designed for 10kV\/12kV overhead distribution lines and distribution transformers. Different from traditional porcelain fuse cutouts, it adopts a high-quality polymer insulator housing, which has the advantages of light weight, corrosion resistance, anti-pollution and UV resistance, and is more suitable for harsh outdoor environments such as coastal salt fog, mountainous strong wind and high-pollution areas. As a cost-effective and reliable protection solution, it is widely used in rural and suburban power grids, industrial and mining enterprises, distributed power generation systems (such as photovoltaic and wind power), and can effectively protect power equipment from overload and short-circuit faults.\u200b<br \/>\nCompliant with international standards such as IEC 60282-2 and national standards GB\/T 15166.3, the product has passed strict type tests (including temperature rise, impulse withstand voltage, short-circuit breaking, etc.), ensuring stable operation in harsh outdoor environments such as high temperature, low temperature, humidity and salt fog. It adopts an advanced arc-extinguishing structure, which can quickly cut off faults and form a visible break, providing a safe maintenance environment for operators.<\/p>\n<div data-page-id=\"PD2ndyDDcoK08sxnNJ3cdgvMnAc\" data-lark-html-role=\"root\" data-docx-has-block-data=\"true\">\n<h2 class=\"heading-2 ace-line old-record-id-OOkGfxCeCdjhxncbBwbcMyOrnQe\">Technical Specifications<\/h2>\n<div>\n<table class=\"ace-table\" data-ace-table-col-widths=\"200;200;200\">\n<colgroup>\n<col width=\"200\" \/>\n<col width=\"200\" \/>\n<col width=\"200\" \/><\/colgroup>\n<tbody>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-HWxzfk5PNdEurOcRqBacEH6Anah\">Parameter Name<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-Gfqkf7MsGdabHjchGAHcS3Q7nWf\">Standard Specification<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-JKD9fo8kbddbF0cOl3ucxkLbnlc\">Remarks<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-K2Mmf0SHAdXdA7cswYnc0SfFnCg\">Rated Voltage<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-BJ1Yf4YmmdDkpmc0J1dcJlhknLb\">12kV (insulation level up to 15kV)<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-SsStfPGLpdBQk4c41bWcCugXnxd\">Suitable for 10kV distribution lines, meeting 15kV level insulation requirements, system maximum voltage \u226412kV<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-WxOlfYc1rdXM0ocmYydc4X8Jn2e\">Rated Current<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-Mvtif7XsYdNhXKc2F2ic8RFDntb\">100A \/ 200A (optional)<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-GcdSf1DajdIWpxcFv8YcwyDoncg\">Customizable (50A-200A), fuse link rated current shall not exceed 80% of the fuse body rated value<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-L7Plf6VUFdZCfPcyvmrcv1U2ndd\">Breaking Current<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-ZMsgfJJktdyQavc3jCecAgbBnDe\">100A model: 8kA; 200A model: 12.5kA<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-PB5Pfz6p6dRXF6c9pSLcjDShnBg\">Reliable arc extinguishing and safe breaking, full breaking time \u226415ms, short-circuit capacity \uff1c250MVA (12kV system)<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-Mk04fH98pdOeSrcqsqhcD95hnag\">Impulse Voltage (BIL)<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-Ij0mfQn33d8QkMcDQPScAzk2nah\">125kV<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-WJ1GfUMlOde1StcMfCec18lFn7e\">Strong lightning protection performance, complying with 1.2\/50\u03bcs waveform standard<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-JqskfYprIdgbYocaUlzclYKCnbd\">Power Frequency Withstand Voltage<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-EQYzfNZlDdrcaJck1WQcW6ZRnUf\">45kV (dry test); 30kV (wet test)<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-N4dff20oLdgUfTcWGUOc0OVpnBg\">Excellent insulation performance, test duration 1 minute<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-Mg43fdJJwd01zbc5UJ2cA4pxnQh\">Creepage Distance<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-XpLDfgfaYdVdjJc3yoHc0g0Qn0e\">380mm (12kV); 450mm (15kV insulation level)<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-BNRwfk7ladrDOJczUdic0lLknUh\">Good anti-pollution performance, suitable for Grade III pollution areas, not suitable for severe pollution and salt fog areas without special treatment<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-Z3glfuuAbd6SvScLwJFcd7zJngc\">Housing Material<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-PYmNfK1HedFsuicXkspcQKaunib\">High-quality epoxy resin polymer (epoxy resin-based composite material)<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-Q7NCfLVvIdSr5mcCtmicMNFWn4g\">Lightweight, anti-aging, UV-resistant, corrosion-resistant, impact strength \u22658J, no brittle fracture at low temperature<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-FMabfzCMwdkeWbcB6qKc0mXKngb\">Contact Material<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-KQU2fAojrd0gz3cyZbVcHmGunMg\">Copper alloy (silver-plated surface)<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-Odi3f4MVudzlEqc2bPIcKMcrnMe\">Low contact resistance (\u226480\u03bc\u03a9), good conductivity, resistant to arc erosion, made of high-conductive copper strip with silver-plated embossments<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-HMLJfizIhdObpPcwXKncsT6Bn5O\">Fuse Tube Material<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-EuhCfwbGudoZEhcKRE4czBzYnvd\">Epoxy glass cloth tube with fiber lining + arc-extinguishing agent<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-IaPGfSPgHdSJkLczCpNcQmlsnwg\">High temperature resistance, strong arc extinguishing ability, mechanical life \u22652000 times, with built-in arc-extinguishing chamber<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-JwssfRb44dUm0HcUUJpcIZbynig\">Operating Temperature<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-HZCgfTcHPdSANFcdPVZcl075nKe\">-40\u2103 ~ +85\u2103<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-ZKCSfFpA0dEEKPc7i6ycm6h5nWf\">Adapting to harsh outdoor environments, normal use temperature range: -30\u2103 ~ +40\u2103<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-DL22fXLjydZPjPcyMLUcTPXJnSb\">Mounting Method<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-RT83fmPOLd98txcnE0OcNujynDg\">Outdoor pole-mounted \/ cross-arm mounted<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-D8baf3BwndoIQacZR7Tcvn5ZnSe\">Easy installation and maintenance, installation angle 25\u00b0\u00b12\u00b0, operation torque \u2264200N\u00b7m, vertical installation required<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-GmMCfyihHdSz5Qcn637cJGHmnYe\">Weight<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-NhoUfZtSjdYhu8c4zdGchbU1nFe\">About 4.2kg<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-UnRSf99erde36CcRwi8cmaeonjg\">Light weight (1\/2 of porcelain fuse cutout), easy to hoist and install<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-UdyrfY0DDdVYWgcs1H5c55PNn9c\">Overall Dimensions<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-XaIgfSyrUdqk8Vc4ZtRcgrJ2nVb\">420\u00d7360\u00d7120mm<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-Ielaf2m1GdgFMWcegYgcjzyEnGc\">Compact structure, small volume, compatible with standard mounting accessories, interchangeable with S&amp;C, Chance, Cooper and ABB models<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-OilRfpLetdLSvYcBfD1cO21Ennf\">Certification<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-Zk4Nf06rQdoawVcMh68cIEVXnQh\">IEC 60282-2, GB\/T 15166.3, GB\/T 15166.2<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-VxkGfQThWd8Z5OcvMO3cFhcVnif\">Meeting international and national standards, passing routine factory inspection<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-AOvyfJT3ndhDKDceLgncbl0Ynte\">Operating Environment<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-YZGhfhiZFdXKbxcPsdDcOdpMn1e\">Altitude \u22641000m; Max wind speed \u226435m\/s; Earthquake intensity \u22648 degrees; No frequent severe vibration<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-NYXafAhVpd2tuzclhurcaRM2n8f\">High-altitude models available for altitude \u22643000m, not suitable for places with combustion, explosion, severe vibration or conductive chemical gases<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-XWu6fAu2JdTMi5cxWexc4168nNc\">Arc Extinguishing Method<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-ETGdfyGxTdag1qcfIQ0cfTvMntb\">Gas-generating arc extinguishing + arc-extinguishing chamber<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-NmaKfFoO5dYwxzc5vm0c2m9lnVc\">Fast arc extinguishing, no arc splashing, arc burning time \uff1c8ms<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-F6isfIwZ0d9NqScFmBYcXuNnnMb\">Mechanical Life<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-C6GofZqX9d6znVc097lcE2Aonsd\">\u22652000 times (closing and opening operations)<\/div>\n<\/td>\n<td colspan=\"1\" rowspan=\"1\">\n<div class=\"ace-line ace-line old-record-id-NJVtfHMYbdkis1cJuzlc7urYnRO\">Hinge structure made of corrosion-resistant copper alloy, flexible rotation<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 class=\"heading-2 ace-line old-record-id-UHwJfu87zd3bUlcbhLwcU2qdnBd\">Product Features (Core Advantages)<\/h2>\n<ul class=\"list-bullet1\">\n<li class=\"ace-line ace-line old-record-id-QIZcfAxbcdOzybcqiW4civHjnPd\" data-list=\"bullet\">\n<div><strong>Lightweight &amp; Easy Installation<\/strong>: Adopt high-quality polymer insulator housing, weight only about 4.2kg, which is 1\/2 of the traditional porcelain fuse cutout, greatly reducing the labor intensity of installation and hoisting, and suitable for high-altitude and difficult installation scenarios.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-FnOpfHJG4dxWrKcbaKrc0zgynOd\" data-list=\"bullet\">\n<div><strong>Superior Anti-pollution &amp; Corrosion Resistance<\/strong>: The polymer housing has excellent anti-pollution performance, with a creepage distance of 380mm (12kV) and 450mm (15kV insulation level), which can stably operate in Grade III pollution areas. It is corrosion-resistant to salt fog, humidity and chemical gases, and has better adaptability than porcelain fuse cutouts in coastal and chemical industrial areas.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-HwWHfbCXJd8A5pccTi7c9fvTnGc\" data-list=\"bullet\">\n<div><strong>Excellent Insulation &amp; Lightning Protection<\/strong>: The impulse withstand voltage reaches 125kV, and the power frequency withstand voltage is 45kV (dry test), with excellent insulation performance, which can effectively prevent insulation breakdown caused by lightning and overvoltage, and ensure the safe operation of the power system.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-Pa5efMR9gdSd6BcMYCBczDNOnjh\" data-list=\"bullet\">\n<div><strong>Reliable Protection &amp; Fast Arc Extinguishing<\/strong>: Equipped with an advanced arc-extinguishing structure and arc-extinguishing agent, the breaking current of 100A model is 8kA, and that of 200A model is 12.5kA. When overload or short circuit occurs, the fuse tube will automatically drop to form a visible break, which is convenient for maintenance personnel to quickly identify faults and improve maintenance efficiency.<\/div>\n<\/li>\n<\/ul>\n<h2 class=\"heading-2 ace-line old-record-id-BRgHfDJi7dOOWlcA9O2cDo88n2g\">Application Scenarios<\/h2>\n<div class=\"ace-line ace-line old-record-id-HKw9fKpREdmQCRcuiEVcAzjznDg\">The HRW12-12-5 12kV\/15kV Polymer Fuse Cutout is mainly used in outdoor high-voltage power systems, with wide adaptability, and its specific application scenarios include:<\/div>\n<ul class=\"list-bullet1\">\n<li class=\"ace-line ace-line old-record-id-GXeYfSVKKdOL4XcnR2Icq33hn4f\" data-list=\"bullet\">\n<div>Protection of 10kV\/12kV outdoor overhead distribution lines, especially suitable for rural and suburban long-span overhead feeders, which can isolate faults without triggering upstream tripping, reducing the power outage range.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-VwNUfr6widlvBEchJeWcQRqMnwb\" data-list=\"bullet\">\n<div>Short-circuit and overload protection of pole-mounted distribution transformers, installed directly before the transformer to protect the transformer from damage caused by downstream faults. It is suitable for 200kVA level transformers and matches the protection requirements of different capacity transformers.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-EISefNQyEdH4lZczhhdc3okGnue\" data-list=\"bullet\">\n<div>Protection of lateral tap points and spur lines of distribution lines, effectively segmenting branch lines from main feeders, minimizing the impact range of faults and improving the reliability of power supply.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-QsLlfTgoSdxzlJcy0BbcjZcSnWn\" data-list=\"bullet\">\n<div>Emergency fault isolation points in power systems, when a fault occurs, the fuse tube drops to give maintenance personnel an intuitive fault prompt, which is convenient for quick troubleshooting and power restoration, improving maintenance efficiency.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-JTkLf9Jydd2MQCcKmfXcWwrZn41\" data-list=\"bullet\">\n<div>Protection of distributed power generation systems, such as photovoltaic power station collection lines and wind farm box transformer high-voltage terminals, which can adapt to the special working conditions of new energy power generation.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-P5nffTRridJvSJcAgOmcfqspnBf\" data-list=\"bullet\">\n<div>Outdoor power distribution systems in industrial and mining enterprises, residential areas, and commercial districts, providing reliable protection for power supply safety. It is also suitable for coastal salt fog areas and mountainous strong wind areas with harsh environmental conditions.<\/div>\n<\/li>\n<\/ul>\n<h2 class=\"heading-2 ace-line old-record-id-Im0XfGVKqdbwhtca7necZKESnqh\">Installation Notes<\/h2>\n<ul class=\"list-bullet1\">\n<li class=\"ace-line ace-line old-record-id-OomVfQYBHd5kA2cMv1cc6PnynAf\" data-list=\"bullet\">\n<div>The installation shall be carried out by professional electricians who have obtained relevant operation certificates to ensure safe operation and avoid electric shock accidents.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-DiQcfJldodQAlXceRNscmcxcnwa\" data-list=\"bullet\">\n<div>When installing, the axis of the fuse tube shall form an angle of 25\u00b0\u00b12\u00b0 with the vertical line, and the contact pressure shall be calibrated to 80-120N to ensure good contact and avoid poor contact caused by loose installation.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-ZmmQfIj9Bd5BiLcFYMvcFu83nUg\" data-list=\"bullet\">\n<div>The distance between two phases shall not be less than 300mm, and the vertical distance from the ground shall be more than 5.5m to meet the safety distance requirement and prevent accidental contact.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-FifbfcaYQdc2Hicayj0cRuXtnch\" data-list=\"bullet\">\n<div>The lead wire shall adopt copper-aluminum transition terminal, the cross-sectional area of copper core lead wire shall not be less than 35mm\u00b2, and the surface of the terminal shall be coated with power composite grease to reduce contact resistance and prevent oxidation.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-KDUXfhWOFd1hxrcKFpKcb2YPn8e\" data-list=\"bullet\">\n<div>After installation, check the flexibility of the mechanical rotating parts, and ensure that the fuse tube can drop reliably when the fuse link is fused, so as to ensure the reliability of fault isolation.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-B2SSfFh6Vd93aScloDScaofRnOR\" data-list=\"bullet\">\n<div>For high-altitude areas above 1000m, the rated current of the fuse shall be reduced by 0.5% for every 100m increase; for III-level pollution areas, silicon rubber anti-pollution skirts can be added to improve anti-pollution performance; for coastal salt fog areas, anti-corrosion treatment of metal parts shall be strengthened.<\/div>\n<\/li>\n<\/ul>\n<h2 class=\"heading-2 ace-line old-record-id-BXQrfDWZRdQoF5cBuu2cDasZnnf\">FAQ<\/h2>\n<ul class=\"list-bullet1\">\n<li class=\"ace-line ace-line old-record-id-SRV3ff99gdWwIGcsfICcJfAGnbe\" data-list=\"bullet\">\n<div><strong>Q: What is the difference between HRW12-12-5 and traditional porcelain fuse cutouts?<\/strong> A: The HRW12-12-5 adopts a polymer insulator housing, which is lighter (only 1\/2 of porcelain fuse cutouts), more corrosion-resistant and anti-pollution, and has better adaptability to harsh environments. It also has excellent insulation and arc-extinguishing performance, and is easier to install and maintain.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-DtkcfN6eudL4ducODXYc8jTUnDg\" data-list=\"bullet\">\n<div><strong>Q: What is the difference between 12kV and 15kV of HRW12-12-5?<\/strong> A: The rated voltage of the product is 12kV (suitable for 10kV distribution lines), and the insulation level reaches 15kV, which means it can withstand the voltage impact of 15kV, with higher safety and wider application range, and can be used in areas with higher insulation requirements.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-IMKufcBchdVqOFcIcxDcTWocn2f\" data-list=\"bullet\">\n<div><strong>Q: Can the rated current be customized?<\/strong> A: Yes, the standard rated current is 100A\/200A, and we can provide customized services of 50A-200A according to your actual needs, which can be matched with different capacity transformers and line loads.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-LXMZfocypdfgcpcQuEIchCConsc\" data-list=\"bullet\">\n<div><strong>Q: What is the service life of this fuse cutout?<\/strong> A: Under normal outdoor working conditions, the service life is more than 15 years, and the fuse link needs to be replaced regularly according to the operation condition (generally 1-2 years). The service life can be extended by regular maintenance and inspection.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-YrCnf4mdcdpntacoJhhcMLE7nJb\" data-list=\"bullet\">\n<div><strong>Q: Is it compatible with other brands of fuse links?<\/strong> A: Yes, the fuse link adopts standard size, which is compatible with most of the same type of polymer fuse cutouts on the market, and the replacement is convenient, reducing the cost of spare parts.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-PDMpfLMI6dx3DEcHcuecWhSFnkr\" data-list=\"bullet\">\n<div><strong>Q: Does it have relevant international certifications?<\/strong> A: Yes, it complies with IEC 60282-2, GB\/T 15166.3 and GB\/T 15166.2 standards, and can provide certification reports according to customer requirements, ensuring that it meets the import and export and project acceptance standards.<\/div>\n<\/li>\n<\/ul>\n<h2 class=\"heading-2 ace-line old-record-id-YkjhfSEFldywBhck0blceNuDnQe\">After-Sales Service<\/h2>\n<ul class=\"list-bullet1\">\n<li class=\"ace-line ace-line old-record-id-Qop1fxtbAdOWeAc5lyBcWd6ondy\" data-list=\"bullet\">\n<div>Warranty Period: 12 months from the date of delivery, free replacement of damaged parts caused by product quality problems during the warranty period, and free technical guidance for installation and maintenance.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-Vpz0fPvZhdituocea9hcYtbenn7\" data-list=\"bullet\">\n<div>Technical Support: Provide professional installation guidance, operation training and fault diagnosis services, and respond to technical questions within 24 hours to solve your use problems in a timely manner.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-WoRNfrJLDdYA4DcdZw3cSu6DnKh\" data-list=\"bullet\">\n<div>Spare Parts Supply: Provide long-term and stable supply of fuse links, polymer housings and other vulnerable parts at preferential prices, ensuring the normal operation of your equipment and reducing maintenance costs.<\/div>\n<\/li>\n<li class=\"ace-line ace-line old-record-id-BwncfjdgKdxmh0cyUJDctwLJnRe\" data-list=\"bullet\">\n<div>Customization Service: According to the customer&#8217;s special needs (such as different rated current, insulation level, installation size, high-altitude and anti-pollution requirements), provide customized design and production services to meet your specific project needs.<\/div>\n<\/li>\n<\/ul>\n<\/div>\n<h2><\/h2>\n<h2><strong>Outline Drawing:<\/strong><\/h2>\n<p>&nbsp;<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-691\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/12KV-Polymer-Fuse-Cutout.jpg\" alt=\"12KV polymer fuse cutout\" width=\"1011\" height=\"522\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/12KV-Polymer-Fuse-Cutout.jpg 1011w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/12KV-Polymer-Fuse-Cutout-300x155.jpg 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/12KV-Polymer-Fuse-Cutout-768x397.jpg 768w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/12KV-Polymer-Fuse-Cutout-600x310.jpg 600w\" sizes=\"(max-width: 1011px) 100vw, 1011px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>HRW12-12-5, 12kV polymer fuse cutout, 15kV polymer fuse cutout, outdoor high voltage polymer fuse, drop-out polymer fuse, HRW12 series fuse cutout, high voltage protection device, IEC standard polymer fuse, 10kV distribution line fuse, lightweight polymer insulator fuse<\/p>","protected":false},"featured_media":692,"template":"","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"","_seopress_titles_desc":"HRW12-12-5 12kV\/15kV Polymer Fuse Cutout, outdoor high voltage drop-out fuse with 100A\/200A rated current, 8kA breaking capacity. Features lightweight polymer insulator, UV-resistant, anti-pollution, IEC standard, ideal for 10kV distribution lines & transformers","_seopress_robots_index":""},"product_brand":[],"product_cat":[42],"product_tag":[],"class_list":{"0":"post-690","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-drop-out-fuse-cutout","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/product\/690","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/media\/692"}],"wp:attachment":[{"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/media?parent=690"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/product_brand?post=690"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/product_cat?post=690"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/th\/wp-json\/wp\/v2\/product_tag?post=690"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}