{"id":732,"date":"2021-04-25T08:01:55","date_gmt":"2021-04-25T08:01:55","guid":{"rendered":"https:\/\/www.wolunelectric.com\/?post_type=product&#038;p=732"},"modified":"2026-04-22T14:35:28","modified_gmt":"2026-04-22T06:35:28","slug":"high-voltage-fuse-link-k-fuse-link-t","status":"publish","type":"product","link":"https:\/\/www.wolunelectric.com\/ru\/product\/high-voltage-fuse-link-k-fuse-link-t\/","title":{"rendered":"\u0412\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u0430\u044f \u043f\u043b\u0430\u0432\u043a\u0430\u044f \u0432\u0441\u0442\u0430\u0432\u043a\u0430 K \u041f\u043b\u0430\u0432\u043a\u0430\u044f \u0432\u0441\u0442\u0430\u0432\u043a\u0430 T"},"content":{"rendered":"<h3><\/h3>\n<p>\u041f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0438 \u0442\u0438\u043f\u0430 \"KB,KU,Ks\" \u043e\u0442\u043d\u043e\u0441\u044f\u0442\u0441\u044f \u043a \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u044f\u043c \u0442\u0438\u043f\u0430 \"K\" \u0438 \"T\". \u041e\u043d\u0438 \u043c\u043e\u0433\u0443\u0442 \u0431\u044b\u0442\u044c \u043e\u0431\u0449\u0435\u0433\u043e \u0442\u0438\u043f\u0430, \u0443\u043d\u0438\u0432\u0435\u0440\u0441\u0430\u043b\u044c\u043d\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0438 \u0432\u0438\u043d\u0442\u043e\u0432\u043e\u0433\u043e \u0442\u0438\u043f\u0430 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441\u043e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043e\u043c IEC282. \u0418\u0437\u0434\u0435\u043b\u0438\u0435 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u0443\u0435\u0442\u0441\u044f \u0434\u043b\u044f \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0435\u0439 \u043d\u0430 11-36 \u043a\u0412.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-733\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/fuse-link-t-type-k-type.png\" alt=\"\u043f\u043b\u0430\u0432\u043a\u0430\u044f \u0432\u0441\u0442\u0430\u0432\u043a\u0430 t \u0442\u0438\u043f\u0430 k \u0442\u0438\u043f\u0430\" width=\"664\" height=\"588\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/fuse-link-t-type-k-type.png 664w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/fuse-link-t-type-k-type-300x266.png 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/fuse-link-t-type-k-type-600x531.png 600w\" sizes=\"(max-width: 664px) 100vw, 664px\" \/><img decoding=\"async\" class=\"alignnone size-full wp-image-734\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/high-voltage-fuse-link-t-type-k-type.png\" alt=\"\u0412\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u0430\u044f \u043f\u043b\u0430\u0432\u043a\u0430\u044f \u0432\u0441\u0442\u0430\u0432\u043a\u0430 \u0442\u0438\u043f\u0430 t \u0442\u0438\u043f\u0430 k \u0442\u0438\u043f\u0430\" width=\"679\" height=\"270\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/high-voltage-fuse-link-t-type-k-type.png 679w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/high-voltage-fuse-link-t-type-k-type-300x119.png 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/04\/high-voltage-fuse-link-t-type-k-type-600x239.png 600w\" sizes=\"(max-width: 679px) 100vw, 679px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2 data-section-id=\"626vum\" data-start=\"1082\" data-end=\"1116\">High Voltage Fuse Link (K Type)<\/h2>\n<h3 data-section-id=\"qg61l5\" data-start=\"1118\" data-end=\"1169\">Fast-Acting Protection for Distribution Systems<\/h3>\n<p data-start=\"1171\" data-end=\"1368\">The <strong data-start=\"1175\" data-end=\"1208\">K type high voltage fuse link<\/strong> is designed for use in <strong data-start=\"1232\" data-end=\"1274\">drop-out fuse cutouts (expulsion type)<\/strong> to provide <strong data-start=\"1286\" data-end=\"1318\">fast and reliable protection<\/strong> for distribution transformers and overhead lines.<\/p>\n<p data-start=\"1370\" data-end=\"1542\">With its <strong data-start=\"1379\" data-end=\"1421\">fast-speed time-current characteristic<\/strong>, the K-rated fuse link quickly responds to fault currents, minimizing equipment damage and improving system reliability.<\/p>\n<hr data-start=\"1544\" data-end=\"1547\" \/>\n<h2 data-section-id=\"dw11pr\" data-start=\"1549\" data-end=\"1567\">\ud83d\udd27 Key Features<\/h2>\n<ul data-start=\"1569\" data-end=\"1934\">\n<li data-section-id=\"qerw6m\" data-start=\"1569\" data-end=\"1633\"><strong data-start=\"1571\" data-end=\"1596\">K Rated (Fast Speed):<\/strong> Quick response to fault conditions<\/li>\n<li data-section-id=\"k9t10h\" data-start=\"1634\" data-end=\"1696\"><strong data-start=\"1636\" data-end=\"1659\">Wide Current Range:<\/strong> Available from low to high ratings<\/li>\n<li data-section-id=\"djgl7l\" data-start=\"1697\" data-end=\"1742\"><strong data-start=\"1699\" data-end=\"1740\">Accurate Time-Current Characteristics<\/strong><\/li>\n<li data-section-id=\"1x120wa\" data-start=\"1743\" data-end=\"1814\"><strong data-start=\"1745\" data-end=\"1775\">Reliable Arc Interruption:<\/strong> Compatible with fuse tube assemblies<\/li>\n<li data-section-id=\"1fvo0ua\" data-start=\"1815\" data-end=\"1854\"><strong data-start=\"1817\" data-end=\"1852\">Easy Installation &amp; Replacement<\/strong><\/li>\n<li data-section-id=\"1ocf6iw\" data-start=\"1855\" data-end=\"1887\"><strong data-start=\"1857\" data-end=\"1885\">High Mechanical Strength<\/strong><\/li>\n<li data-section-id=\"1kzg74y\" data-start=\"1888\" data-end=\"1934\"><strong data-start=\"1890\" data-end=\"1934\">Stable Performance in Outdoor Conditions<\/strong><\/li>\n<\/ul>\n<hr data-start=\"1936\" data-end=\"1939\" \/>\n<h2 data-section-id=\"1h9ugi6\" data-start=\"1941\" data-end=\"1971\">\u2699\ufe0f Technical Specifications<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1973\" data-end=\"2251\">\n<thead data-start=\"1973\" data-end=\"1994\">\n<tr data-start=\"1973\" data-end=\"1994\">\n<th class=\"\" data-start=\"1973\" data-end=\"1985\" data-col-size=\"sm\">\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th class=\"\" data-start=\"1985\" data-end=\"1994\" data-col-size=\"sm\">\u0417\u043d\u0430\u0447\u0435\u043d\u0438\u0435<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2015\" data-end=\"2251\">\n<tr data-start=\"2015\" data-end=\"2043\">\n<td data-start=\"2015\" data-end=\"2022\" data-col-size=\"sm\">\u0422\u0438\u043f<\/td>\n<td data-col-size=\"sm\" data-start=\"2022\" data-end=\"2043\">K Rated Fuse Link<\/td>\n<\/tr>\n<tr data-start=\"2044\" data-end=\"2075\">\n<td data-start=\"2044\" data-end=\"2060\" data-col-size=\"sm\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td>\n<td data-col-size=\"sm\" data-start=\"2060\" data-end=\"2075\">11kV \u2013 36kV<\/td>\n<\/tr>\n<tr data-start=\"2076\" data-end=\"2105\">\n<td data-start=\"2076\" data-end=\"2092\" data-col-size=\"sm\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a<\/td>\n<td data-col-size=\"sm\" data-start=\"2092\" data-end=\"2105\">1A \u2013 200A<\/td>\n<\/tr>\n<tr data-start=\"2106\" data-end=\"2130\">\n<td data-start=\"2106\" data-end=\"2118\" data-col-size=\"sm\">Frequency<\/td>\n<td data-col-size=\"sm\" data-start=\"2118\" data-end=\"2130\">50\/60 Hz<\/td>\n<\/tr>\n<tr data-start=\"2131\" data-end=\"2167\">\n<td data-start=\"2131\" data-end=\"2151\" data-col-size=\"sm\">Breaking Capacity<\/td>\n<td data-start=\"2151\" data-end=\"2167\" data-col-size=\"sm\">Up to 12.5kA<\/td>\n<\/tr>\n<tr data-start=\"2168\" data-end=\"2206\">\n<td data-start=\"2168\" data-end=\"2179\" data-col-size=\"sm\">Material<\/td>\n<td data-start=\"2179\" data-end=\"2206\" data-col-size=\"sm\">Silver \/ Copper Element<\/td>\n<\/tr>\n<tr data-start=\"2207\" data-end=\"2251\">\n<td data-start=\"2207\" data-end=\"2221\" data-col-size=\"sm\">\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0435<\/td>\n<td data-start=\"2221\" data-end=\"2251\" data-col-size=\"sm\">Drop-out Fuse Cutout (FCO)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"2253\" data-end=\"2301\"><em data-start=\"2253\" data-end=\"2301\">Custom current ratings available upon request.<\/em><\/p>\n<hr data-start=\"2303\" data-end=\"2306\" \/>\n<h2 data-section-id=\"1q6yyp4\" data-start=\"2308\" data-end=\"2340\">\u26a1 Time-Current Characteristic<\/h2>\n<ul data-start=\"2342\" data-end=\"2530\">\n<li data-section-id=\"5hja3b\" data-start=\"2342\" data-end=\"2401\"><strong data-start=\"2344\" data-end=\"2362\">K Type (Fast):<\/strong> \u0633\u0631\u064a\u0639 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0648\u0627\u0644\u062e\u0637\u0648\u0637<\/li>\n<li data-section-id=\"jmnmou\" data-start=\"2402\" data-end=\"2466\">Suitable for applications requiring <strong data-start=\"2440\" data-end=\"2464\">rapid fault clearing<\/strong><\/li>\n<li data-section-id=\"1219hiy\" data-start=\"2467\" data-end=\"2530\">Helps reduce <strong data-start=\"2482\" data-end=\"2515\">thermal and mechanical stress<\/strong> on equipment<\/li>\n<\/ul>\n<hr data-start=\"2532\" data-end=\"2535\" \/>\n<h2 data-section-id=\"173fulk\" data-start=\"2537\" data-end=\"2556\">\ud83c\udfd7\ufe0f Applications<\/h2>\n<p data-start=\"2558\" data-end=\"2595\">K type fuse links are widely used in:<\/p>\n<ul data-start=\"2597\" data-end=\"2755\">\n<li data-section-id=\"bod3gq\" data-start=\"2597\" data-end=\"2636\">Distribution transformer protection<\/li>\n<li data-section-id=\"gn4g8z\" data-start=\"2637\" data-end=\"2665\">Overhead line protection<\/li>\n<li data-section-id=\"dsx9tx\" data-start=\"2666\" data-end=\"2697\">Rural and urban power grids<\/li>\n<li data-section-id=\"1nqwvtx\" data-start=\"2698\" data-end=\"2721\">Utility substations<\/li>\n<li data-section-id=\"1cd0bw7\" data-start=\"2722\" data-end=\"2755\">Industrial electrical systems<\/li>\n<\/ul>\n<hr data-start=\"2757\" data-end=\"2760\" \/>\n<h2 data-section-id=\"o48ijg\" data-start=\"2762\" data-end=\"2794\">\ud83c\udd9a K Type vs T Type Fuse Link<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2796\" data-end=\"3036\">\n<thead data-start=\"2796\" data-end=\"2825\">\n<tr data-start=\"2796\" data-end=\"2825\">\n<th class=\"\" data-start=\"2796\" data-end=\"2806\" data-col-size=\"sm\">\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430<\/th>\n<th class=\"\" data-start=\"2806\" data-end=\"2815\" data-col-size=\"sm\">K Type<\/th>\n<th class=\"\" data-start=\"2815\" data-end=\"2825\" data-col-size=\"sm\">T Type<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2855\" data-end=\"3036\">\n<tr data-start=\"2855\" data-end=\"2878\">\n<td data-start=\"2855\" data-end=\"2863\" data-col-size=\"sm\">Speed<\/td>\n<td data-start=\"2863\" data-end=\"2870\" data-col-size=\"sm\">Fast<\/td>\n<td data-start=\"2870\" data-end=\"2878\" data-col-size=\"sm\">Slow<\/td>\n<\/tr>\n<tr data-start=\"2879\" data-end=\"2956\">\n<td data-start=\"2879\" data-end=\"2893\" data-col-size=\"sm\">\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0435<\/td>\n<td data-start=\"2893\" data-end=\"2925\" data-col-size=\"sm\">Transformer \/ line protection<\/td>\n<td data-start=\"2925\" data-end=\"2956\" data-col-size=\"sm\">Inrush current applications<\/td>\n<\/tr>\n<tr data-start=\"2957\" data-end=\"2992\">\n<td data-start=\"2957\" data-end=\"2973\" data-col-size=\"sm\">Response Time<\/td>\n<td data-start=\"2973\" data-end=\"2981\" data-col-size=\"sm\">Quick<\/td>\n<td data-start=\"2981\" data-end=\"2992\" data-col-size=\"sm\">Delayed<\/td>\n<\/tr>\n<tr data-start=\"2993\" data-end=\"3036\">\n<td data-start=\"2993\" data-end=\"3012\" data-col-size=\"sm\">Protection Style<\/td>\n<td data-start=\"3012\" data-end=\"3024\" data-col-size=\"sm\">Sensitive<\/td>\n<td data-start=\"3024\" data-end=\"3036\" data-col-size=\"sm\">Tolerant<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"3038\" data-end=\"3041\" \/>\n<h2 data-section-id=\"kt2j6s\" data-start=\"3043\" data-end=\"3078\">\ud83c\udf0d Advantages for Export Markets<\/h2>\n<ul data-start=\"3080\" data-end=\"3319\">\n<li data-section-id=\"1i0mcsx\" data-start=\"3080\" data-end=\"3124\">Compatible with <strong data-start=\"3098\" data-end=\"3122\">IEC \/ ANSI standards<\/strong><\/li>\n<li data-section-id=\"h82chd\" data-start=\"3125\" data-end=\"3185\">High demand in <strong data-start=\"3142\" data-end=\"3183\">South America, Africa, Southeast Asia<\/strong><\/li>\n<li data-section-id=\"1q819ac\" data-start=\"3186\" data-end=\"3243\">Suitable for <strong data-start=\"3201\" data-end=\"3241\">EPC projects and utility maintenance<\/strong><\/li>\n<li data-section-id=\"vc7jtl\" data-start=\"3244\" data-end=\"3284\">OEM packaging and branding available<\/li>\n<li data-section-id=\"1rtfp80\" data-start=\"3285\" data-end=\"3319\">Stable quality for bulk supply<\/li>\n<\/ul>\n<hr data-start=\"3321\" data-end=\"3324\" \/>\n<h2 data-section-id=\"pvnji3\" data-start=\"3326\" data-end=\"3352\">\ud83d\udce6 Packaging &amp; Delivery<\/h2>\n<ul data-start=\"3354\" data-end=\"3492\">\n<li data-section-id=\"1tb779k\" data-start=\"3354\" data-end=\"3383\">Standard export packaging<\/li>\n<li data-section-id=\"9z5pu4\" data-start=\"3384\" data-end=\"3424\">Bulk or individual packing available<\/li>\n<li data-section-id=\"qklej8\" data-start=\"3425\" data-end=\"3457\">Delivery time: <strong data-start=\"3442\" data-end=\"3455\">7\u201315 days<\/strong><\/li>\n<li data-section-id=\"jittc4\" data-start=\"3458\" data-end=\"3492\">Trade terms: <strong data-start=\"3473\" data-end=\"3492\">EXW \/ FOB \/ CIF<\/strong><\/li>\n<\/ul>\n<hr data-start=\"3494\" data-end=\"3497\" \/>\n<h2 data-section-id=\"154jn03\" data-start=\"3499\" data-end=\"3528\">\ud83c\udfed Manufacturer Capability<\/h2>\n<p data-start=\"3530\" data-end=\"3596\">We supply a full range of <strong data-start=\"3556\" data-end=\"3584\">fuse protection products<\/strong>, including:<\/p>\n<ul data-start=\"3598\" data-end=\"3719\">\n<li data-section-id=\"lhse7j\" data-start=\"3598\" data-end=\"3630\">Fuse Links (K type \/ T type)<\/li>\n<li data-section-id=\"jmu4tg\" data-start=\"3631\" data-end=\"3669\">Fuse Cutouts (Porcelain &amp; Polymer)<\/li>\n<li data-section-id=\"jjrzub\" data-start=\"3670\" data-end=\"3694\">Fuse Tube Assemblies<\/li>\n<li data-section-id=\"1uqkuoz\" data-start=\"3695\" data-end=\"3719\">Mounting Accessories<\/li>\n<\/ul>\n<p data-start=\"3721\" data-end=\"3785\">Serving <strong data-start=\"3729\" data-end=\"3784\">global distributors, utilities, and EPC contractors<\/strong>.<\/p>\n<hr data-start=\"3787\" data-end=\"3790\" \/>\n<h2 data-section-id=\"1udw84c\" data-start=\"3792\" data-end=\"3809\">\ud83d\udce9 Get a Quote<\/h2>\n<p data-start=\"3811\" data-end=\"3881\">Looking for a reliable supplier of <strong data-start=\"3846\" data-end=\"3880\">K type high voltage fuse links<\/strong>?<\/p>\n<p data-start=\"3883\" data-end=\"3902\">Contact us now for:<\/p>\n<ul data-start=\"3903\" data-end=\"4006\">\n<li data-section-id=\"1hlxxfe\" data-start=\"3903\" data-end=\"3937\">Fast quotation within 24 hours<\/li>\n<li data-section-id=\"1m6ue7r\" data-start=\"3938\" data-end=\"3974\">Time-current curves &amp; datasheets<\/li>\n<li data-section-id=\"fsa6qb\" data-start=\"3975\" data-end=\"4006\">Competitive factory pricing<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>\u0412\u044b\u0441\u043e\u043a\u043e\u0432\u043e\u043b\u044c\u0442\u043d\u0430\u044f \u043f\u043b\u0430\u0432\u043a\u0430\u044f \u0432\u0441\u0442\u0430\u0432\u043a\u0430 K, \u043f\u043b\u0430\u0432\u043a\u0430\u044f \u0432\u0441\u0442\u0430\u0432\u043a\u0430 T, \u043f\u043b\u0430\u0432\u043a\u0430\u044f \u0432\u0441\u0442\u0430\u0432\u043a\u0430 \u0434\u043b\u044f \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u0435\u0434\u043e\u0445\u0440\u0430\u043d\u0438\u0442\u0435\u043b\u0435\u0439<\/p>","protected":false},"featured_media":735,"template":"","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"High Voltage Fuse Link K Type | K Rated Fuse Link for Drop-out Fuse Cutout","_seopress_titles_desc":"Buy K type fuse link for high voltage fuse cutouts. Fast melting characteristic, easy replacement, and ideal for utility and EPC applications.","_seopress_robots_index":""},"product_brand":[],"product_cat":[42],"product_tag":[],"class_list":{"0":"post-732","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-drop-out-fuse-cutout","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product\/732","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/media\/735"}],"wp:attachment":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/media?parent=732"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product_brand?post=732"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product_cat?post=732"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product_tag?post=732"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}