{"id":3441,"date":"2026-04-01T12:41:02","date_gmt":"2026-04-01T04:41:02","guid":{"rendered":"https:\/\/www.wolunelectric.com\/?post_type=product&#038;p=3441"},"modified":"2026-05-20T10:11:43","modified_gmt":"2026-05-20T02:11:43","slug":"arc-extinguish-chamber-for-outdoor-pole-mounted-air-load-break-switch","status":"publish","type":"product","link":"https:\/\/www.wolunelectric.com\/ru\/product\/arc-extinguish-chamber-for-outdoor-pole-mounted-air-load-break-switch\/","title":{"rendered":"Arc Extinguish Chamber for Outdoor Pole Mounted Air Load Break Switch"},"content":{"rendered":"<p data-start=\"73\" data-end=\"713\">The Arc Extinguish Chamber is a critical component used in outdoor pole mounted air load break switches (LBS) for interrupting load current safely and efficiently. Designed for medium voltage distribution systems from 12kV to 40.5kV, the chamber utilizes compressed gas and arc splitting technology to rapidly extinguish electrical arcs during switching operations, ensuring reliable network protection and operational safety. The arc extinguishing chamber is widely used in FKW18 series outdoor air insulated load break switches for overhead distribution lines, substations, and utility power systems.<\/p>\n<h2 data-section-id=\"736h55\" data-start=\"715\" data-end=\"734\">\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0442\u043e\u0432\u0430\u0440\u0430<\/h2>\n<ul data-start=\"736\" data-end=\"1151\">\n<li data-section-id=\"hbdr6l\" data-start=\"736\" data-end=\"779\">High efficiency arc quenching performance<\/li>\n<li data-section-id=\"t5vz6v\" data-start=\"780\" data-end=\"843\">Suitable for 12kV, 24kV, 36kV, and 40.5kV load break switches<\/li>\n<li data-section-id=\"1pghing\" data-start=\"844\" data-end=\"886\">Excellent insulation and heat resistance<\/li>\n<li data-section-id=\"1h03xf1\" data-start=\"887\" data-end=\"929\">Durable UV-resistant insulating material<\/li>\n<li data-section-id=\"1pxvnka\" data-start=\"930\" data-end=\"972\">Compact structure with easy installation<\/li>\n<li data-section-id=\"15o7bnb\" data-start=\"973\" data-end=\"1018\">Long mechanical and electrical service life<\/li>\n<li data-section-id=\"aks983\" data-start=\"1019\" data-end=\"1066\">Reliable operation under outdoor environments<\/li>\n<li data-section-id=\"71gwy5\" data-start=\"1067\" data-end=\"1097\">Low maintenance requirements<\/li>\n<li data-section-id=\"mhbynl\" data-start=\"1098\" data-end=\"1151\">Compatible with manual and motorized LBS mechanisms<\/li>\n<\/ul>\n<h2 data-section-id=\"1cgu054\" data-start=\"1153\" data-end=\"1180\">\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1182\" data-end=\"1660\">\n<thead data-start=\"1182\" data-end=\"1206\">\n<tr data-start=\"1182\" data-end=\"1206\">\n<th class=\"last:pe-10\" data-start=\"1182\" data-end=\"1189\" data-col-size=\"sm\">\u0410\u0440\u0442\u0438\u043a\u0443\u043b<\/th>\n<th class=\"last:pe-10\" data-start=\"1189\" data-end=\"1206\" data-col-size=\"md\">\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1217\" data-end=\"1660\">\n<tr data-start=\"1217\" data-end=\"1258\">\n<td data-start=\"1217\" data-end=\"1232\" data-col-size=\"sm\">Product Name<\/td>\n<td data-col-size=\"md\" data-start=\"1232\" data-end=\"1258\">Arc Extinguish Chamber<\/td>\n<\/tr>\n<tr data-start=\"1259\" data-end=\"1306\">\n<td data-start=\"1259\" data-end=\"1273\" data-col-size=\"sm\">\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u0435<\/td>\n<td data-col-size=\"md\" data-start=\"1273\" data-end=\"1306\">Outdoor Air Load Break Switch<\/td>\n<\/tr>\n<tr data-start=\"1307\" data-end=\"1354\">\n<td data-start=\"1307\" data-end=\"1323\" data-col-size=\"sm\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td>\n<td data-col-size=\"md\" data-start=\"1323\" data-end=\"1354\">12kV \/ 24kV \/ 36kV \/ 40.5kV<\/td>\n<\/tr>\n<tr data-start=\"1355\" data-end=\"1394\">\n<td data-start=\"1355\" data-end=\"1371\" data-col-size=\"sm\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a<\/td>\n<td data-col-size=\"md\" data-start=\"1371\" data-end=\"1394\">400A \/ 630A \/ 1250A<\/td>\n<\/tr>\n<tr data-start=\"1395\" data-end=\"1422\">\n<td data-start=\"1395\" data-end=\"1407\" data-col-size=\"sm\">Frequency<\/td>\n<td data-col-size=\"md\" data-start=\"1407\" data-end=\"1422\">50Hz \/ 60Hz<\/td>\n<\/tr>\n<tr data-start=\"1423\" data-end=\"1454\">\n<td data-start=\"1423\" data-end=\"1438\" data-col-size=\"sm\">Installation<\/td>\n<td data-col-size=\"md\" data-start=\"1438\" data-end=\"1454\">Pole Mounted<\/td>\n<\/tr>\n<tr data-start=\"1455\" data-end=\"1524\">\n<td data-start=\"1455\" data-end=\"1482\" data-col-size=\"sm\">Arc Extinguishing Method<\/td>\n<td data-col-size=\"md\" data-start=\"1482\" data-end=\"1524\">Gas Generation &amp; Air Arc Extinguishing<\/td>\n<\/tr>\n<tr data-start=\"1525\" data-end=\"1586\">\n<td data-start=\"1525\" data-end=\"1536\" data-col-size=\"sm\">Material<\/td>\n<td data-start=\"1536\" data-end=\"1586\" data-col-size=\"md\">High Temperature Resistant Insulation Material<\/td>\n<\/tr>\n<tr data-start=\"1587\" data-end=\"1622\">\n<td data-start=\"1587\" data-end=\"1611\" data-col-size=\"sm\">Operating Environment<\/td>\n<td data-col-size=\"md\" data-start=\"1611\" data-end=\"1622\">Outdoor<\/td>\n<\/tr>\n<tr data-start=\"1623\" data-end=\"1660\">\n<td data-start=\"1623\" data-end=\"1635\" data-col-size=\"sm\">\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b<\/td>\n<td data-start=\"1635\" data-end=\"1660\" data-col-size=\"md\">IEC 60265 \/ IEC 62271<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2 data-section-id=\"1p8ivm\" data-start=\"1662\" data-end=\"1682\">Working Principle<\/h2>\n<p data-start=\"1684\" data-end=\"2130\">When the load break switch opens under load conditions, an electric arc forms between the contacts. The arc extinguish chamber rapidly cools and elongates the arc using gas generation and airflow control mechanisms, reducing ionization and extinguishing the arc safely at current zero crossing. This design significantly improves switching reliability and protects the switch contacts from excessive erosion.<\/p>\n<h2 data-section-id=\"mu966k\" data-start=\"2132\" data-end=\"2147\">\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f<\/h2>\n<p data-start=\"2149\" data-end=\"2194\">The arc extinguish chamber is widely used in:<\/p>\n<ul data-start=\"2196\" data-end=\"2430\">\n<li data-section-id=\"j6mpap\" data-start=\"2196\" data-end=\"2231\">Outdoor load break switches (LBS)<\/li>\n<li data-section-id=\"qg4ty\" data-start=\"2232\" data-end=\"2266\">Pole mounted disconnect switches<\/li>\n<li data-section-id=\"jsaieu\" data-start=\"2267\" data-end=\"2311\">Medium voltage overhead distribution lines<\/li>\n<li data-section-id=\"lsqbyd\" data-start=\"2312\" data-end=\"2341\">Rural and urban power grids<\/li>\n<li data-section-id=\"p1b3xh\" data-start=\"2342\" data-end=\"2363\">Utility substations<\/li>\n<li data-section-id=\"1fz2kme\" data-start=\"2364\" data-end=\"2396\">Transformer protection systems<\/li>\n<li data-section-id=\"3uyl7q\" data-start=\"2397\" data-end=\"2430\">Ring main distribution networks<\/li>\n<\/ul>\n<h2 data-section-id=\"5woqdp\" data-start=\"2432\" data-end=\"2459\">Compatible Switch Models<\/h2>\n<ul data-start=\"2461\" data-end=\"2653\">\n<li data-section-id=\"kegtza\" data-start=\"2461\" data-end=\"2497\">FKW18-12 Outdoor Load Break Switch<\/li>\n<li data-section-id=\"wpc0bn\" data-start=\"2498\" data-end=\"2534\">FKW18-24 Outdoor Load Break Switch<\/li>\n<li data-section-id=\"wc977e\" data-start=\"2535\" data-end=\"2573\">FKW18-40.5 Outdoor Load Break Switch<\/li>\n<li data-section-id=\"gm7tv7\" data-start=\"2574\" data-end=\"2616\">Pole mounted air insulated load switches<\/li>\n<li data-section-id=\"hakqlv\" data-start=\"2617\" data-end=\"2653\">Medium voltage disconnect switches<\/li>\n<\/ul>\n<h2 data-section-id=\"dysc5y\" data-start=\"2655\" data-end=\"2676\">Product Advantages<\/h2>\n<h3 data-section-id=\"11dydc1\" data-start=\"2678\" data-end=\"2707\">Reliable Arc Interruption<\/h3>\n<p data-start=\"2708\" data-end=\"2801\">Provides stable and efficient arc extinguishing performance during load switching operations.<\/p>\n<h3 data-section-id=\"cvgblj\" data-start=\"2803\" data-end=\"2824\">Long Service Life<\/h3>\n<p data-start=\"2825\" data-end=\"2923\">High-quality insulating materials offer excellent resistance to heat, UV, and environmental aging.<\/p>\n<h3 data-section-id=\"1juax8v\" data-start=\"2925\" data-end=\"2944\">Low Maintenance<\/h3>\n<p data-start=\"2945\" data-end=\"3038\">Simple structural design minimizes maintenance workload and improves operational reliability.<\/p>\n<h3 data-section-id=\"h82yo2\" data-start=\"3040\" data-end=\"3073\">Excellent Outdoor Performance<\/h3>\n<p data-start=\"3074\" data-end=\"3181\">Suitable for harsh environmental conditions including high humidity, pollution, and temperature variations.<\/p>\n<h2 data-section-id=\"hczsjz\" data-start=\"3183\" data-end=\"3204\">Packaging &amp; Supply<\/h2>\n<ul data-start=\"3206\" data-end=\"3349\">\n<li data-section-id=\"1nhnw8z\" data-start=\"3206\" data-end=\"3245\">Standard export carton or wooden case<\/li>\n<li data-section-id=\"1i29zaj\" data-start=\"3246\" data-end=\"3275\">OEM &amp; ODM service available<\/li>\n<li data-section-id=\"7tx6ec\" data-start=\"3276\" data-end=\"3306\">Spare parts supply supported<\/li>\n<li data-section-id=\"1gzo238\" data-start=\"3307\" data-end=\"3349\">Custom dimensions available upon request<\/li>\n<\/ul>\n<pre><\/pre>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-3459\" src=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-11.png\" alt=\"arc extinguish chamber for outdoor pole mounted air load break switch\" width=\"666\" height=\"560\" \/><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-3460\" src=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-Dimension.avif\" alt=\"arc extinguish chamber for outdoor pole mounted air load break switch\" width=\"743\" height=\"673\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-Dimension.avif 743w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-Dimension-13x12.avif 13w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-Dimension-600x543.avif 600w\" sizes=\"(max-width: 743px) 100vw, 743px\" \/><\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-3444\" src=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-3-scaled.webp\" alt=\"arc extinguish chamber for outdoor pole mounted air load break switch\" width=\"702\" height=\"526\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-3-scaled.webp 1920w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-3-768x576.webp 768w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-3-1536x1152.webp 1536w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-3-16x12.webp 16w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-3-600x450.webp 600w\" sizes=\"(max-width: 702px) 100vw, 702px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3447\" src=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-2.webp\" alt=\"arc extinguish chamber for outdoor pole mounted air load break switch\" width=\"432\" height=\"317\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-2.webp 432w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-2-16x12.webp 16w\" sizes=\"(max-width: 432px) 100vw, 432px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3446\" src=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-4.webp\" alt=\"arc extinguish chamber for outdoor pole mounted air load break switch\" width=\"450\" height=\"800\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-4.webp 450w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-4-7x12.webp 7w\" sizes=\"(max-width: 450px) 100vw, 450px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3445\" src=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-5.webp\" alt=\"arc extinguish chamber for outdoor pole mounted air load break switch\" width=\"466\" height=\"761\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-5.webp 1175w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-5-768x1255.webp 768w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-5-940x1536.webp 940w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-5-7x12.webp 7w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2026\/04\/Arc-Extinguish-Chamber-for-Outdoor-Pole-Mounted-Air-Load-Break-Switch-5-600x981.webp 600w\" sizes=\"(max-width: 466px) 100vw, 466px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>The arc extinguish chamber is a key component used in outdoor pole mounted air load break switches (LBS) for safe interruption of load current.<\/p>\n<p>Designed for medium voltage distribution systems, it provides fast arc quenching, high insulation performance, and reliable switching operation for 12kV\u201336kV outdoor load break switches. Suitable for utility, substation, and overhead line applications.<\/p>","protected":false},"featured_media":3459,"template":"","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"Arc Extinguish Chamber for Outdoor Pole Mounted Air Load Break Switch","_seopress_titles_desc":"High voltage arc extinguish chamber for outdoor pole mounted air load break switches. Suitable for 12kV, 24kV, and 36kV LBS applications with reliable arc quenching performance and long service life.","_seopress_robots_index":""},"product_brand":[],"product_cat":[46],"product_tag":[],"class_list":{"0":"post-3441","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-high-voltage-disconnect-switch","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product\/3441","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/media\/3459"}],"wp:attachment":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/media?parent=3441"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product_brand?post=3441"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product_cat?post=3441"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product_tag?post=3441"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}