{"id":3289,"date":"2025-03-20T11:27:44","date_gmt":"2025-03-20T03:27:44","guid":{"rendered":"https:\/\/www.wolunelectric.com\/?post_type=product&#038;p=3289"},"modified":"2026-05-20T10:32:10","modified_gmt":"2026-05-20T02:32:10","slug":"vna-10-630-vna-10-400-load-switches","status":"publish","type":"product","link":"https:\/\/www.wolunelectric.com\/ru\/product\/vna-10-630-vna-10-400-load-switches\/","title":{"rendered":"BHA-10\/630 BHA-10\/400 \u041f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438"},"content":{"rendered":"<p data-start=\"41\" data-end=\"581\">The VNA-10 series indoor load break switches are medium voltage switching devices designed for operational switching of three-phase AC power systems under load conditions.<\/p>\n<p data-start=\"41\" data-end=\"581\">Available in 400A and 630A rated current versions, the VNA-10 load switches are widely used in indoor switchgear, transformer substations, KSO cabinets, and ring main distribution systems for 6kV\u201310kV networks.<\/p>\n<p data-start=\"41\" data-end=\"581\">The switches utilize an auto-gas arc extinguishing chamber to ensure reliable load interruption and operational safety.<\/p>\n<h2 data-section-id=\"736h55\" data-start=\"583\" data-end=\"602\">\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0442\u043e\u0432\u0430\u0440\u0430<\/h2>\n<ul data-start=\"604\" data-end=\"973\">\n<li data-section-id=\"1sntu2\" data-start=\"604\" data-end=\"625\">Rated voltage: 10kV<\/li>\n<li data-section-id=\"5wbqhf\" data-start=\"626\" data-end=\"654\">Rated current: 400A \/ 630A<\/li>\n<li data-section-id=\"ybq5tb\" data-start=\"655\" data-end=\"687\">Indoor air insulated structure<\/li>\n<li data-section-id=\"1ffo1af\" data-start=\"688\" data-end=\"727\">Auto-gas arc extinguishing technology<\/li>\n<li data-section-id=\"tx3se4\" data-start=\"728\" data-end=\"765\">Reliable load switching performance<\/li>\n<li data-section-id=\"165k42m\" data-start=\"766\" data-end=\"793\">Optional grounding blades<\/li>\n<li data-section-id=\"17e5quy\" data-start=\"794\" data-end=\"835\">Manual or motorized operation available<\/li>\n<li data-section-id=\"uesi57\" data-start=\"836\" data-end=\"879\">Compact design for switchgear integration<\/li>\n<li data-section-id=\"ff2l1w\" data-start=\"880\" data-end=\"903\">Visible isolation gap<\/li>\n<li data-section-id=\"1ft1fe4\" data-start=\"904\" data-end=\"932\">High mechanical durability<\/li>\n<li data-section-id=\"c6g6wh\" data-start=\"933\" data-end=\"973\">Polymer or porcelain insulator options<\/li>\n<\/ul>\n<h2 data-section-id=\"1cgu054\" data-start=\"975\" data-end=\"1002\">\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" style=\"height: 534px;\" width=\"729\" data-start=\"1004\" data-end=\"1480\">\n<thead data-start=\"1004\" data-end=\"1038\">\n<tr data-start=\"1004\" data-end=\"1038\">\n<th class=\"last:pe-10\" data-start=\"1004\" data-end=\"1011\" data-col-size=\"sm\">\u0410\u0440\u0442\u0438\u043a\u0443\u043b<\/th>\n<th class=\"last:pe-10\" data-start=\"1011\" data-end=\"1024\" data-col-size=\"sm\">VNA-10\/400<\/th>\n<th class=\"last:pe-10\" data-start=\"1024\" data-end=\"1038\" data-col-size=\"sm\">VNA-10\/630<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1053\" data-end=\"1480\">\n<tr data-start=\"1053\" data-end=\"1084\">\n<td data-start=\"1053\" data-end=\"1069\" data-col-size=\"sm\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td>\n<td data-col-size=\"sm\" data-start=\"1069\" data-end=\"1076\">10kV<\/td>\n<td data-col-size=\"sm\" data-start=\"1076\" data-end=\"1084\">10kV<\/td>\n<\/tr>\n<tr data-start=\"1085\" data-end=\"1128\">\n<td data-start=\"1085\" data-end=\"1113\" data-col-size=\"sm\">Maximum Operating Voltage<\/td>\n<td data-col-size=\"sm\" data-start=\"1113\" data-end=\"1120\">12 \u043a\u0412<\/td>\n<td data-col-size=\"sm\" data-start=\"1120\" data-end=\"1128\">12 \u043a\u0412<\/td>\n<\/tr>\n<tr data-start=\"1129\" data-end=\"1160\">\n<td data-start=\"1129\" data-end=\"1145\" data-col-size=\"sm\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a<\/td>\n<td data-col-size=\"sm\" data-start=\"1145\" data-end=\"1152\">400A<\/td>\n<td data-col-size=\"sm\" data-start=\"1152\" data-end=\"1160\">630A<\/td>\n<\/tr>\n<tr data-start=\"1161\" data-end=\"1201\">\n<td data-start=\"1161\" data-end=\"1186\" data-col-size=\"sm\">Rated Breaking Current<\/td>\n<td data-col-size=\"sm\" data-start=\"1186\" data-end=\"1193\">400A<\/td>\n<td data-col-size=\"sm\" data-start=\"1193\" data-end=\"1201\">630A<\/td>\n<\/tr>\n<tr data-start=\"1202\" data-end=\"1255\">\n<td data-start=\"1202\" data-end=\"1230\" data-col-size=\"sm\">Thermal Withstand Current<\/td>\n<td data-col-size=\"sm\" data-start=\"1230\" data-end=\"1242\">20kA \/ 1s<\/td>\n<td data-col-size=\"sm\" data-start=\"1242\" data-end=\"1255\">20kA \/ 1s<\/td>\n<\/tr>\n<tr data-start=\"1256\" data-end=\"1296\">\n<td data-start=\"1256\" data-end=\"1281\" data-col-size=\"sm\">Peak Withstand Current<\/td>\n<td data-col-size=\"sm\" data-start=\"1281\" data-end=\"1288\">51kA<\/td>\n<td data-col-size=\"sm\" data-start=\"1288\" data-end=\"1296\">51kA<\/td>\n<\/tr>\n<tr data-start=\"1297\" data-end=\"1338\">\n<td data-start=\"1297\" data-end=\"1309\" data-col-size=\"sm\">Frequency<\/td>\n<td data-start=\"1309\" data-end=\"1323\" data-col-size=\"sm\">50Hz \/ 60Hz<\/td>\n<td data-col-size=\"sm\" data-start=\"1323\" data-end=\"1338\">50Hz \/ 60Hz<\/td>\n<\/tr>\n<tr data-start=\"1339\" data-end=\"1394\">\n<td data-start=\"1339\" data-end=\"1357\" data-col-size=\"sm\">Mechanical Life<\/td>\n<td data-start=\"1357\" data-end=\"1375\" data-col-size=\"sm\">2000 Operations<\/td>\n<td data-col-size=\"sm\" data-start=\"1375\" data-end=\"1394\">2000 Operations<\/td>\n<\/tr>\n<tr data-start=\"1395\" data-end=\"1429\">\n<td data-start=\"1395\" data-end=\"1410\" data-col-size=\"sm\">Installation<\/td>\n<td data-col-size=\"sm\" data-start=\"1410\" data-end=\"1419\">Indoor<\/td>\n<td data-col-size=\"sm\" data-start=\"1419\" data-end=\"1429\">Indoor<\/td>\n<\/tr>\n<tr data-start=\"1430\" data-end=\"1480\">\n<td data-start=\"1430\" data-end=\"1457\" data-col-size=\"sm\">Arc Extinguishing Method<\/td>\n<td data-col-size=\"sm\" data-start=\"1457\" data-end=\"1468\">Auto-Gas<\/td>\n<td data-col-size=\"sm\" data-start=\"1468\" data-end=\"1480\">Auto-Gas<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"1482\" data-end=\"1519\">\n<h2 data-section-id=\"1p8ivm\" data-start=\"1521\" data-end=\"1541\">Working Principle<\/h2>\n<p data-start=\"1543\" data-end=\"1887\">The VNA load switch uses a self-generated gas arc extinguishing chamber. During switching operations, the electric arc formed between contacts heats the chamber material, generating gas that rapidly cools and extinguishes the arc. This ensures safe interruption of load currents and minimizes contact wear.<\/p>\n<h2 data-section-id=\"mu966k\" data-start=\"1889\" data-end=\"1904\">\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f<\/h2>\n<p data-start=\"1906\" data-end=\"1952\">The VNA-10 load switches are commonly used in:<\/p>\n<ul data-start=\"1954\" data-end=\"2166\">\n<li data-section-id=\"zsriu7\" data-start=\"1954\" data-end=\"1980\">Indoor switchgear panels<\/li>\n<li data-section-id=\"1poxyi7\" data-start=\"1981\" data-end=\"2004\">Ring main units (RMU)<\/li>\n<li data-section-id=\"bgm5uf\" data-start=\"2005\" data-end=\"2044\">Compact transformer substations (KTP)<\/li>\n<li data-section-id=\"1c8wb3x\" data-start=\"2045\" data-end=\"2067\">KSO and KRU cabinets<\/li>\n<li data-section-id=\"160yndo\" data-start=\"2068\" data-end=\"2107\">Industrial power distribution systems<\/li>\n<li data-section-id=\"p1b3xh\" data-start=\"2108\" data-end=\"2129\">Utility substations<\/li>\n<li data-section-id=\"18del2g\" data-start=\"2130\" data-end=\"2166\">Mining and infrastructure projects<\/li>\n<\/ul>\n<h2 data-section-id=\"dysc5y\" data-start=\"2168\" data-end=\"2189\">Product Advantages<\/h2>\n<h3 data-section-id=\"2k1q7e\" data-start=\"2191\" data-end=\"2217\">Reliable Arc Quenching<\/h3>\n<p data-start=\"2218\" data-end=\"2304\">Auto-gas arc extinguishing technology provides stable and efficient load interruption.<\/p>\n<h3 data-section-id=\"lnez84\" data-start=\"2306\" data-end=\"2327\">Compact Structure<\/h3>\n<p data-start=\"2328\" data-end=\"2417\">Ideal for installation inside medium voltage switchgear cabinets and compact substations.<\/p>\n<h3 data-section-id=\"mo8j42\" data-start=\"2419\" data-end=\"2437\">Safe Operation<\/h3>\n<p data-start=\"2438\" data-end=\"2516\">Mechanical interlocking prevents incorrect grounding and switching operations.<\/p>\n<h3 data-section-id=\"cvgblj\" data-start=\"2518\" data-end=\"2539\">Long Service Life<\/h3>\n<p data-start=\"2540\" data-end=\"2616\">Designed for high operational reliability with low maintenance requirements.<\/p>\n<h2 data-section-id=\"ef99d4\" data-start=\"2618\" data-end=\"2644\">Optional Configurations<\/h2>\n<ul data-start=\"2646\" data-end=\"2845\">\n<li data-section-id=\"1t9saco\" data-start=\"2646\" data-end=\"2691\">Left-side or right-side operating mechanism<\/li>\n<li data-section-id=\"190r381\" data-start=\"2692\" data-end=\"2731\">Grounding blades on one or both sides<\/li>\n<li data-section-id=\"e9ifnw\" data-start=\"2732\" data-end=\"2755\">Fuse combination type<\/li>\n<li data-section-id=\"nr1bwn\" data-start=\"2756\" data-end=\"2783\">Polymer insulator version<\/li>\n<li data-section-id=\"vgrno6\" data-start=\"2784\" data-end=\"2813\">Porcelain insulator version<\/li>\n<li data-section-id=\"9as1fb\" data-start=\"2814\" data-end=\"2845\">Motorized operating mechanism<\/li>\n<\/ul>\n<div class=\"auto-hide-last-sibling-br table-container-cVc1zm\"><\/div>\n<h2>\u0413\u0430\u0431\u0430\u0440\u0438\u0442\u043d\u044b\u0439 \u0447\u0435\u0440\u0442\u0435\u0436<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-3292\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-LOAD-SWITCHES-DRAWING.jpg\" alt=\"\u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 vna 10\/630 vna 10\/400\" width=\"1067\" height=\"539\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-LOAD-SWITCHES-DRAWING.jpg 1067w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-LOAD-SWITCHES-DRAWING-300x152.jpg 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-LOAD-SWITCHES-DRAWING-1024x517.jpg 1024w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-LOAD-SWITCHES-DRAWING-768x388.jpg 768w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-LOAD-SWITCHES-DRAWING-18x9.jpg 18w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-LOAD-SWITCHES-DRAWING-600x303.jpg 600w\" sizes=\"(max-width: 1067px) 100vw, 1067px\" \/><\/p>\n<div><\/div>\n<div>\u00a0\u00a0\u00a0<img decoding=\"async\" class=\"alignnone wp-image-3296\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-10-400-load-switches-scaled.jpg\" alt=\"\u043f\u0435\u0440\u0435\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u0438 \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 vna 10\/630 vna 10\/400\" width=\"669\" height=\"502\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-10-400-load-switches-scaled.jpg 2560w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-10-400-load-switches-300x225.jpg 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-10-400-load-switches-1024x768.jpg 1024w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-10-400-load-switches-768x576.jpg 768w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-10-400-load-switches-1536x1152.jpg 1536w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-10-400-load-switches-2048x1536.jpg 2048w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-10-400-load-switches-16x12.jpg 16w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2025\/03\/VNA-10-400-load-switches-600x450.jpg 600w\" sizes=\"(max-width: 669px) 100vw, 669px\" \/><\/div>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>VNA-10\/630 and VNA-10\/400 are indoor medium voltage load break switches designed for 6kV\u201310kV power distribution systems.<\/p>\n<p>Featuring reliable auto-gas arc extinguishing performance, compact structure, and optional grounding blades, they are ideal for substations, switchgear panels, and transformer protection applications.<\/p>","protected":false},"featured_media":3295,"template":"","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"VNA-10\/630 & VNA-10\/400 Load Switches | 10kV Indoor Load Break Switch","_seopress_titles_desc":"VNA-10\/630 and VNA-10\/400 indoor load break switches for 10kV medium voltage systems. Reliable auto-gas arc extinguishing technology, compact design, and optional grounding switch configuration.","_seopress_robots_index":""},"product_brand":[],"product_cat":[82,46],"product_tag":[],"class_list":{"0":"post-3289","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-russia-type-products","7":"product_cat-high-voltage-disconnect-switch","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product\/3289","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/media\/3295"}],"wp:attachment":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/media?parent=3289"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product_brand?post=3289"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product_cat?post=3289"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product_tag?post=3289"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}