{"id":2001,"date":"2021-12-23T11:26:12","date_gmt":"2021-12-23T03:26:12","guid":{"rendered":"https:\/\/www.wolunelectric.com\/?post_type=product&#038;p=2001"},"modified":"2026-05-20T10:55:07","modified_gmt":"2026-05-20T02:55:07","slug":"fn5-12kv-24kv-indoor-load-break-switch","status":"publish","type":"product","link":"https:\/\/www.wolunelectric.com\/ru\/product\/fn5-12kv-24kv-indoor-load-break-switch\/","title":{"rendered":"FN5 12 \u043a\u0412 24 \u043a\u0412 \u0412\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0432\u043d\u0443\u0442\u0440\u0438 \u043f\u043e\u043c\u0435\u0449\u0435\u043d\u0438\u044f"},"content":{"rendered":"<p data-start=\"42\" data-end=\"616\">The FN5 series indoor high voltage load break switch is an air insulated medium voltage switching device designed for 12kV and 24kV AC power distribution systems.<\/p>\n<p data-start=\"42\" data-end=\"616\">It is widely used in ring main units (RMU), compact substations, switchgear panels, and industrial distribution networks for load switching, overload protection, and short-circuit interruption when combined with high voltage current limiting fuses.<\/p>\n<p data-start=\"42\" data-end=\"616\">The FN5 load switch features compact structure, reliable arc extinguishing performance, and integrated grounding capability.<\/p>\n<h2 data-section-id=\"736h55\" data-start=\"618\" data-end=\"637\">\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0442\u043e\u0432\u0430\u0440\u0430<\/h2>\n<ul data-start=\"639\" data-end=\"1065\">\n<li data-section-id=\"1ok11jw\" data-start=\"639\" data-end=\"667\">Rated voltage: 12kV \/ 24kV<\/li>\n<li data-section-id=\"5wbqhf\" data-start=\"668\" data-end=\"696\">Rated current: 400A \/ 630A<\/li>\n<li data-section-id=\"ybq5tb\" data-start=\"697\" data-end=\"729\">Indoor air insulated structure<\/li>\n<li data-section-id=\"evkfix\" data-start=\"730\" data-end=\"774\">Three-position operation: ON \/ OFF \/ EARTH<\/li>\n<li data-section-id=\"ktlypd\" data-start=\"775\" data-end=\"811\">Reliable load breaking performance<\/li>\n<li data-section-id=\"twz3ot\" data-start=\"812\" data-end=\"840\">Fuse combination available<\/li>\n<li data-section-id=\"avbvpt\" data-start=\"841\" data-end=\"865\">Compact modular design<\/li>\n<li data-section-id=\"3b2kim\" data-start=\"866\" data-end=\"916\">Manual or motorized operating mechanism optional<\/li>\n<li data-section-id=\"ff2l1w\" data-start=\"917\" data-end=\"940\">Visible isolation gap<\/li>\n<li data-section-id=\"9gj8yu\" data-start=\"941\" data-end=\"979\">Integrated grounding switch optional<\/li>\n<li data-section-id=\"1tgmrm1\" data-start=\"980\" data-end=\"1022\">Suitable for RMU and compact substations<\/li>\n<li data-section-id=\"1dlisa1\" data-start=\"1023\" data-end=\"1065\">High mechanical and electrical endurance<\/li>\n<\/ul>\n<h2 data-section-id=\"1cgu054\" data-start=\"1067\" data-end=\"1094\">\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" style=\"height: 400px;\" width=\"725\" data-start=\"1096\" data-end=\"1586\">\n<thead data-start=\"1096\" data-end=\"1122\">\n<tr data-start=\"1096\" data-end=\"1122\">\n<th class=\"last:pe-10\" data-start=\"1096\" data-end=\"1103\" data-col-size=\"sm\">\u0410\u0440\u0442\u0438\u043a\u0443\u043b<\/th>\n<th class=\"last:pe-10\" data-start=\"1103\" data-end=\"1112\" data-col-size=\"sm\">FN5-12<\/th>\n<th class=\"last:pe-10\" data-start=\"1112\" data-end=\"1122\" data-col-size=\"sm\">FN5-24<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1137\" data-end=\"1586\">\n<tr data-start=\"1137\" data-end=\"1168\">\n<td data-start=\"1137\" data-end=\"1153\" data-col-size=\"sm\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td>\n<td data-start=\"1153\" data-end=\"1160\" data-col-size=\"sm\">12 \u043a\u0412<\/td>\n<td data-start=\"1160\" data-end=\"1168\" data-col-size=\"sm\">24 \u043a\u0412<\/td>\n<\/tr>\n<tr data-start=\"1169\" data-end=\"1214\">\n<td data-start=\"1169\" data-end=\"1185\" data-col-size=\"sm\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a<\/td>\n<td data-start=\"1185\" data-end=\"1199\" data-col-size=\"sm\">400A \/ 630A<\/td>\n<td data-start=\"1199\" data-end=\"1214\" data-col-size=\"sm\">400A \/ 630A<\/td>\n<\/tr>\n<tr data-start=\"1215\" data-end=\"1262\">\n<td data-start=\"1215\" data-end=\"1233\" data-col-size=\"sm\">\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u0447\u0430\u0441\u0442\u043e\u0442\u0430<\/td>\n<td data-start=\"1233\" data-end=\"1247\" data-col-size=\"sm\">50Hz \/ 60Hz<\/td>\n<td data-start=\"1247\" data-end=\"1262\" data-col-size=\"sm\">50Hz \/ 60Hz<\/td>\n<\/tr>\n<tr data-start=\"1263\" data-end=\"1315\">\n<td data-start=\"1263\" data-end=\"1300\" data-col-size=\"sm\">Rated Short-Time Withstand Current<\/td>\n<td data-start=\"1300\" data-end=\"1307\" data-col-size=\"sm\">20kA<\/td>\n<td data-start=\"1307\" data-end=\"1315\" data-col-size=\"sm\">20kA<\/td>\n<\/tr>\n<tr data-start=\"1316\" data-end=\"1376\">\n<td data-start=\"1316\" data-end=\"1347\" data-col-size=\"sm\">Rated Peak Withstand Current<\/td>\n<td data-start=\"1347\" data-end=\"1361\" data-col-size=\"sm\">50kA \/ 63kA<\/td>\n<td data-start=\"1361\" data-end=\"1376\" data-col-size=\"sm\">50kA \/ 63kA<\/td>\n<\/tr>\n<tr data-start=\"1377\" data-end=\"1430\">\n<td data-start=\"1377\" data-end=\"1417\" data-col-size=\"sm\">Rated Cable Charging Breaking Current<\/td>\n<td data-start=\"1417\" data-end=\"1423\" data-col-size=\"sm\">10A<\/td>\n<td data-start=\"1423\" data-end=\"1430\" data-col-size=\"sm\">10A<\/td>\n<\/tr>\n<tr data-start=\"1431\" data-end=\"1485\">\n<td data-start=\"1431\" data-end=\"1469\" data-col-size=\"sm\">Lightning Impulse Withstand Voltage<\/td>\n<td data-start=\"1469\" data-end=\"1476\" data-col-size=\"sm\">75kV<\/td>\n<td data-start=\"1476\" data-end=\"1485\" data-col-size=\"sm\">125kV<\/td>\n<\/tr>\n<tr data-start=\"1486\" data-end=\"1551\">\n<td data-start=\"1486\" data-end=\"1509\" data-col-size=\"sm\">Mechanical Endurance<\/td>\n<td data-start=\"1509\" data-end=\"1532\" data-col-size=\"sm\">1000\u20132000 Operations<\/td>\n<td data-start=\"1532\" data-end=\"1551\" data-col-size=\"sm\">2000 Operations<\/td>\n<\/tr>\n<tr data-start=\"1552\" data-end=\"1586\">\n<td data-start=\"1552\" data-end=\"1567\" data-col-size=\"sm\">Installation<\/td>\n<td data-start=\"1567\" data-end=\"1576\" data-col-size=\"sm\">Indoor<\/td>\n<td data-start=\"1576\" data-end=\"1586\" data-col-size=\"sm\">Indoor<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"1588\" data-end=\"1625\">\n<h2 data-section-id=\"1p8ivm\" data-start=\"1627\" data-end=\"1647\">Working Principle<\/h2>\n<p data-start=\"1649\" data-end=\"2058\">The FN5 indoor load break switch adopts an air arc extinguishing chamber combined with a spring operating mechanism. During opening operations, the contacts separate rapidly and the generated arc is cooled and extinguished by the arc chamber. Fuse-switch combination versions can automatically interrupt short-circuit currents to provide transformer and cable protection.<\/p>\n<h2 data-section-id=\"141ftwt\" data-start=\"2060\" data-end=\"2082\">Main Configurations<\/h2>\n<h3 data-section-id=\"as2wx7\" data-start=\"2084\" data-end=\"2118\">FN5 Standard Load Break Switch<\/h3>\n<ul data-start=\"2119\" data-end=\"2220\">\n<li data-section-id=\"ms3d0\" data-start=\"2119\" data-end=\"2150\">Basic load switching function<\/li>\n<li data-section-id=\"8rch6k\" data-start=\"2151\" data-end=\"2190\">Suitable for line and cable switching<\/li>\n<li data-section-id=\"11pk1du\" data-start=\"2191\" data-end=\"2220\">Compact indoor installation<\/li>\n<\/ul>\n<h3 data-section-id=\"1npchr4\" data-start=\"2222\" data-end=\"2253\">FN5-R Fuse Combination Type<\/h3>\n<ul data-start=\"2254\" data-end=\"2382\">\n<li data-section-id=\"w7djxp\" data-start=\"2254\" data-end=\"2296\">Integrated current limiting fuse holders<\/li>\n<li data-section-id=\"1oksj8q\" data-start=\"2297\" data-end=\"2333\">Transformer protection application<\/li>\n<li data-section-id=\"176tqet\" data-start=\"2334\" data-end=\"2382\">Enhanced short-circuit interruption capability<\/li>\n<\/ul>\n<h3 data-section-id=\"incz3c\" data-start=\"2384\" data-end=\"2414\">FN5-D with Earthing Switch<\/h3>\n<ul data-start=\"2415\" data-end=\"2511\">\n<li data-section-id=\"1ea7zl4\" data-start=\"2415\" data-end=\"2444\">Integrated grounding switch<\/li>\n<li data-section-id=\"jca0gf\" data-start=\"2445\" data-end=\"2481\">Mechanical interlocking protection<\/li>\n<li data-section-id=\"1u9jw2\" data-start=\"2482\" data-end=\"2511\">Improved operational safety<\/li>\n<\/ul>\n<h2 data-section-id=\"mu966k\" data-start=\"2513\" data-end=\"2528\">\u041f\u0440\u0438\u043b\u043e\u0436\u0435\u043d\u0438\u044f<\/h2>\n<p data-start=\"2530\" data-end=\"2581\">The FN5 indoor load break switch is widely used in:<\/p>\n<ul data-start=\"2583\" data-end=\"2834\">\n<li data-section-id=\"reme7j\" data-start=\"2583\" data-end=\"2606\">Ring Main Units (RMU)<\/li>\n<li data-section-id=\"zsriu7\" data-start=\"2607\" data-end=\"2633\">Indoor switchgear panels<\/li>\n<li data-section-id=\"311rbt\" data-start=\"2634\" data-end=\"2667\">Compact transformer substations<\/li>\n<li data-section-id=\"160yndo\" data-start=\"2668\" data-end=\"2707\">Industrial power distribution systems<\/li>\n<li data-section-id=\"p1b3xh\" data-start=\"2708\" data-end=\"2729\">Utility substations<\/li>\n<li data-section-id=\"1epz1fx\" data-start=\"2730\" data-end=\"2758\">Cable distribution systems<\/li>\n<li data-section-id=\"12gldt2\" data-start=\"2759\" data-end=\"2789\">Renewable energy substations<\/li>\n<li data-section-id=\"19j6m0a\" data-start=\"2790\" data-end=\"2834\">Urban medium voltage distribution networks<\/li>\n<\/ul>\n<h2 data-section-id=\"dysc5y\" data-start=\"2836\" data-end=\"2857\">Product Advantages<\/h2>\n<h3 data-section-id=\"idlrtg\" data-start=\"2859\" data-end=\"2893\">Reliable Switching Performance<\/h3>\n<p data-start=\"2894\" data-end=\"2986\">Provides stable load interruption and safe switching operation under normal load conditions.<\/p>\n<h3 data-section-id=\"lnez84\" data-start=\"2988\" data-end=\"3009\">Compact Structure<\/h3>\n<p data-start=\"3010\" data-end=\"3089\">Small size and lightweight design suitable for compact switchgear applications.<\/p>\n<h3 data-section-id=\"199xlgy\" data-start=\"3091\" data-end=\"3116\">Integrated Protection<\/h3>\n<p data-start=\"3117\" data-end=\"3193\">Fuse combination type offers reliable overload and short-circuit protection.<\/p>\n<h3 data-section-id=\"mo8j42\" data-start=\"3195\" data-end=\"3213\">Safe Operation<\/h3>\n<p data-start=\"3214\" data-end=\"3292\">Mechanical interlocking prevents incorrect grounding and switching operations.<\/p>\n<h2 data-section-id=\"uoahhp\" data-start=\"3294\" data-end=\"3317\">Optional Accessories<\/h2>\n<ul data-start=\"3319\" data-end=\"3490\">\n<li data-section-id=\"f31nn2\" data-start=\"3319\" data-end=\"3353\">CS6-1 manual operating mechanism<\/li>\n<li data-section-id=\"y6c59h\" data-start=\"3354\" data-end=\"3381\">Motor operating mechanism<\/li>\n<li data-section-id=\"1wfsxrl\" data-start=\"3382\" data-end=\"3402\">Auxiliary contacts<\/li>\n<li data-section-id=\"1dh3ds9\" data-start=\"3403\" data-end=\"3424\">Fuse trip mechanism<\/li>\n<li data-section-id=\"v7h4v\" data-start=\"3425\" data-end=\"3443\">Grounding switch<\/li>\n<li data-section-id=\"nprob2\" data-start=\"3444\" data-end=\"3467\">Remote control system<\/li>\n<li data-section-id=\"19iddgs\" data-start=\"3468\" data-end=\"3490\">Mechanical interlock<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2><b><strong>\u0413\u0430\u0431\u0430\u0440\u0438\u0442\u043d\u044b\u0435 \u0438 \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043e\u0447\u043d\u044b\u0435 \u0440\u0430\u0437\u043c\u0435\u0440\u044b<\/strong><\/b><\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone  wp-image-2003\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/12\/FN5-load-break-switch-drawing.jpg\" alt=\"\u0447\u0435\u0440\u0442\u0435\u0436 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044f \u043d\u0430\u0433\u0440\u0443\u0437\u043a\u0438 fn5\" width=\"1111\" height=\"613\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/12\/FN5-load-break-switch-drawing.jpg 1284w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/12\/FN5-load-break-switch-drawing-300x165.jpg 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/12\/FN5-load-break-switch-drawing-1024x565.jpg 1024w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/12\/FN5-load-break-switch-drawing-768x423.jpg 768w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/12\/FN5-load-break-switch-drawing-600x331.jpg 600w\" sizes=\"(max-width: 1111px) 100vw, 1111px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>FN5 12kV 24kV indoor load break switch is an air insulated medium voltage switch designed for RMU, substations, and switchgear systems.<\/p>\n<p>Featuring compact structure, reliable arc extinguishing technology, and optional fuse combination, it provides safe and efficient load switching for power distribution applications.<\/p>","protected":false},"featured_media":2004,"template":"","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"FN5 12kV 24kV Indoor Load Break Switch | Medium Voltage Air Load Switch","_seopress_titles_desc":"FN5 12kV 24kV indoor load break switch for medium voltage distribution systems. Compact air insulated design with fuse combination, grounding switch, and reliable load interruption performance.","_seopress_robots_index":""},"product_brand":[],"product_cat":[46],"product_tag":[],"class_list":{"0":"post-2001","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-high-voltage-disconnect-switch","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product\/2001","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/media\/2004"}],"wp:attachment":[{"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/media?parent=2001"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product_brand?post=2001"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product_cat?post=2001"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ru\/wp-json\/wp\/v2\/product_tag?post=2001"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}