GW4-12 Chave de desconexão de alta tensão externa de 12kV

GW4-12 outdoor high voltage disconnect switch is designed for 12kV outdoor AC distribution systems. It provides reliable no-load isolation, visible disconnection, and safe operation for substations and overhead power networks.

Informação adicional

Detalhes do produto:

The GW4-12 series outdoor disconnect switch adopts a double-column horizontal opening structure and is suitable for outdoor installations in substations, transformer stations, overhead distribution systems, and industrial power networks.

It is designed to:

  • isolate energized circuits under no-load conditions,
  • provide a visible disconnection point,
  • improve maintenance safety,
  • support manual or motorized operation.

The switch can be equipped with:

  • single grounding switch,
  • double grounding switch,
  • anti-pollution insulators,
  • electric operating mechanism.

It complies with IEC and GB standards for high-voltage disconnect switches.

Main Features

  • Rated voltage: 12kV
  • Outdoor installation type
  • Double-column horizontal break structure
  • Visible isolation gap
  • Manual or motorized operation
  • Optional grounding switch
  • Reliable mechanical interlocking
  • Anti-pollution insulation design
  • Long service life
  • Suitable for harsh outdoor environments

Especificações técnicas

Item Especificação
Tensão nominal 12kV
Maximum Operating Voltage 12kV / 15kV
Frequência nominal 50/60Hz
Corrente nominal 200A / 400A / 630A / 1250A
Rated Short-Time Withstand Current 12.5kA / 20kA / 25kA
Rated Peak Withstand Current 31.5kA / 50kA / 63kA
Short-Circuit Duration 4s
Power Frequency Withstand Voltage 42kV / 48kV
Lightning Impulse Withstand Voltage 75kV / 85kV
Mechanical Life ≥2000 operations
Installation Type Outdoor

Significado do modelo

Typical models include:

  • GW4-12/400
  • GW4-12/630
  • GW4-12D/1250-25
  • GW4-12W/630

Meaning:

  • GW = Outdoor disconnect switch
  • 4 = Design serial number
  • 12 = Rated voltage (kV)
  • D = With grounding switch
  • W = Anti-pollution type
  • 400 / 630 / 1250 = Rated current (A)
  • 25 = Short-time withstand current (kA)

Condições de trabalho

  • Ambient temperature: -25°C to +40°C
  • Altitude: ≤2000m or ≤3000m
  • Wind speed: ≤35m/s
  • Pollution degree: III
  • Intensidade do terremoto: ≤8 graus
  • Installation environment should be free from:
    • explosive materials,
    • corrosive gases,
    • severe vibration.

Aplicativos

  • Outdoor substations
  • Overhead distribution lines
  • Transformer isolation systems
  • Industrial switchyards
  • Renewable energy substations
  • Utility power distribution networks

Product Advantages

Reliable Outdoor Performance

Designed for long-term operation under rain, UV exposure, dust, and polluted environments.

Visible Isolation

Provides a clear visible break to ensure operator and maintenance safety.

Flexible Configuration

Supports manual operation, motorized operation, and grounding switch configurations.

Strong Mechanical Structure

Stable mechanical linkage ensures reliable synchronization and long service life.

Padrões

The GW4-12 disconnect switch generally complies with:

  • IEC 62271-102
  • GB 1985
  • IEC 60129

Desenho de contorno

dimensão da chave seccionadora gw4 12kv

pt_BRPortuguese

Solicite uma cotação rápida