{"id":1119,"date":"2021-05-12T06:37:40","date_gmt":"2021-05-12T06:37:40","guid":{"rendered":"https:\/\/www.wolunelectric.com\/?post_type=product&#038;p=1119"},"modified":"2026-05-18T15:39:40","modified_gmt":"2026-05-18T07:39:40","slug":"lzzbj10-10q-10kv-indoor-current-transformer-cast-resin-current-transformer","status":"publish","type":"product","link":"https:\/\/www.wolunelectric.com\/id\/product\/lzzbj10-10q-10kv-indoor-current-transformer-cast-resin-current-transformer\/","title":{"rendered":"LZZBJ10-10Q 10kV Trafo Arus Dalam Ruangan Trafo Arus Resin Cor"},"content":{"rendered":"<p>&nbsp;<\/p>\n<h2><strong>Pengantar Umum<\/strong><\/h2>\n<p>LZZBJ10-10Q is an indoor epoxy resin cast current transformer designed for 10kV medium voltage power systems. It is mainly used for current measurement, electric energy metering and relay protection in indoor switchgear, substations and distribution equipment.<\/p>\n<p>The transformer adopts fully enclosed epoxy resin casting insulation structure with excellent dielectric performance, moisture resistance and mechanical strength. It is suitable for AC systems with rated frequency 50Hz or 60Hz and rated voltage up to 10kV.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Model &amp; Makna<\/strong><\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone  wp-image-1120\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer.jpg\" alt=\"Trafo arus resin cor dalam ruangan 12kV\" width=\"780\" height=\"470\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer.jpg 478w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer-300x181.jpg 300w\" sizes=\"(max-width: 780px) 100vw, 780px\" \/><\/p>\n<h2>Fitur Produk<\/h2>\n<p>Fully enclosed epoxy resin cast insulation<br \/>\nExcellent insulation and moisture resistance<br \/>\nHigh dynamic and thermal stability<br \/>\nAccurate metering and relay protection performance<br \/>\nCompact structure for switchgear installation<br \/>\nMaintenance-free operation<br \/>\nLong service life<br \/>\nSuitable for high humidity and polluted environments<\/p>\n<h2 data-section-id=\"mu966k\" data-start=\"1692\" data-end=\"1707\">Aplikasi<\/h2>\n<p data-start=\"1709\" data-end=\"1761\">LZZBJ10-10Q current transformers are widely used in:<\/p>\n<ul data-start=\"1763\" data-end=\"1962\">\n<li data-section-id=\"uzwj5g\" data-start=\"1763\" data-end=\"1790\">Medium voltage switchgear<\/li>\n<li data-section-id=\"rqu3sq\" data-start=\"1791\" data-end=\"1810\">Power substations<\/li>\n<li data-section-id=\"atveas\" data-start=\"1811\" data-end=\"1828\">Ring main units<\/li>\n<li data-section-id=\"g0thw7\" data-start=\"1829\" data-end=\"1852\">Distribution cabinets<\/li>\n<li data-section-id=\"114lgxj\" data-start=\"1853\" data-end=\"1878\">Energy metering systems<\/li>\n<li data-section-id=\"rsop9a\" data-start=\"1879\" data-end=\"1905\">Relay protection systems<\/li>\n<li data-section-id=\"5irm6i\" data-start=\"1906\" data-end=\"1937\">Industrial power distribution<\/li>\n<li data-section-id=\"1xwmdbu\" data-start=\"1938\" data-end=\"1962\">Utility power networks<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2><strong>Spesifikasi Teknis<\/strong><\/h2>\n<p>Performa produk sesuai dengan standar IEC dan Trafo Arus GB1208-2006.<\/p>\n<p>Rated insulation level: 12\/42\/75kV\u00a0Rated frequency: 50Hz<\/p>\n<p>Nilai arus sekunder: 5A, 1A<\/p>\n<p>Partial discharge level: In conformity to GB5583-85 standard, its partial discharge is not more than 20PC.<\/p>\n<p><img decoding=\"async\" class=\"alignnone  wp-image-1121\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer-1.jpg\" alt=\"Trafo arus resin cor dalam ruangan 12kV\" width=\"1265\" height=\"752\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer-1.jpg 1051w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer-1-300x178.jpg 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer-1-1024x609.jpg 1024w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer-1-768x457.jpg 768w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer-1-600x357.jpg 600w\" sizes=\"(max-width: 1265px) 100vw, 1265px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Gambar Garis Besar<\/strong><\/h2>\n<p><img decoding=\"async\" class=\"alignnone  wp-image-1122\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer-2.jpg\" alt=\"trafo arus resin cor\" width=\"1245\" height=\"756\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer-2.jpg 1013w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer-2-300x182.jpg 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer-2-768x466.jpg 768w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2021\/05\/LZZBJ10-10Q-10kV-Indoor-Current-Transformer-Cast-Resin-Current-Transformer-2-600x364.jpg 600w\" sizes=\"(max-width: 1245px) 100vw, 1245px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2 data-section-id=\"1hryhf7\" data-start=\"3280\" data-end=\"3286\">FAQ<\/h2>\n<h3 data-section-id=\"a1seq9\" data-start=\"3288\" data-end=\"3348\">What is the function of LZZBJ10-10Q current transformer?<\/h3>\n<p data-start=\"3350\" data-end=\"3469\">It is used for current measurement, electric energy metering and relay protection in medium voltage electrical systems.<\/p>\n<h3 data-section-id=\"6fhjzz\" data-start=\"3471\" data-end=\"3517\">Can customized current ratios be provided?<\/h3>\n<p data-start=\"3519\" data-end=\"3629\">Yes. Customized current ratios, accuracy classes and burdens are available according to customer requirements.<\/p>\n<h3 data-section-id=\"1ezza7u\" data-start=\"3631\" data-end=\"3681\">Which standards does this product comply with?<\/h3>\n<p data-start=\"3683\" data-end=\"3789\">The transformer complies with IEC 61869-2 and GB1208-2006 standards.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>LZZBJ10-10Q is an indoor epoxy resin cast current transformer designed for 10kV medium voltage power systems.<\/p>\n<p>It is widely used for current measurement, electric energy metering and relay protection in indoor switchgear, substations and distribution equipment, featuring compact structure, reliable insulation and stable performance.<\/p>","protected":false},"featured_media":1123,"template":"","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"LZZBJ10-10Q 10kV Indoor Cast Resin Current Transformer","_seopress_titles_desc":"LZZBJ10-10Q 10kV indoor cast resin current transformer for current measurement, energy metering and relay protection in medium voltage switchgear and power distribution systems.","_seopress_robots_index":""},"product_brand":[],"product_cat":[64],"product_tag":[],"class_list":{"0":"post-1119","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ctpt","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.wolunelectric.com\/id\/wp-json\/wp\/v2\/product\/1119","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wolunelectric.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wolunelectric.com\/id\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wolunelectric.com\/id\/wp-json\/wp\/v2\/media\/1123"}],"wp:attachment":[{"href":"https:\/\/www.wolunelectric.com\/id\/wp-json\/wp\/v2\/media?parent=1119"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/id\/wp-json\/wp\/v2\/product_brand?post=1119"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/id\/wp-json\/wp\/v2\/product_cat?post=1119"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/id\/wp-json\/wp\/v2\/product_tag?post=1119"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}