Sakelar Beban VNA-10/630 VNA-10/400

VNA-10/630 and VNA-10/400 are indoor medium voltage load break switches designed for 6kV–10kV power distribution systems.

Featuring reliable auto-gas arc extinguishing performance, compact structure, and optional grounding blades, they are ideal for substations, switchgear panels, and transformer protection applications.

Informasi Tambahan

Detail Produk:

The VNA-10 series indoor load break switches are medium voltage switching devices designed for operational switching of three-phase AC power systems under load conditions.

Available in 400A and 630A rated current versions, the VNA-10 load switches are widely used in indoor switchgear, transformer substations, KSO cabinets, and ring main distribution systems for 6kV–10kV networks.

The switches utilize an auto-gas arc extinguishing chamber to ensure reliable load interruption and operational safety.

Fitur Produk

  • Rated voltage: 10kV
  • Rated current: 400A / 630A
  • Indoor air insulated structure
  • Auto-gas arc extinguishing technology
  • Reliable load switching performance
  • Optional grounding blades
  • Manual or motorized operation available
  • Compact design for switchgear integration
  • Visible isolation gap
  • High mechanical durability
  • Polymer or porcelain insulator options

Spesifikasi Teknis

Item VNA-10/400 VNA-10/630
Tegangan Pengenal 10kV 10kV
Maximum Operating Voltage 12kV 12kV
Nilai Saat Ini 400A 630A
Rated Breaking Current 400A 630A
Thermal Withstand Current 20kA / 1s 20kA / 1s
Peak Withstand Current 51kA 51kA
Frequency 50Hz / 60Hz 50Hz / 60Hz
Mechanical Life 2000 Operations 2000 Operations
Installation Indoor Indoor
Arc Extinguishing Method Auto-Gas Auto-Gas

Working Principle

The VNA load switch uses a self-generated gas arc extinguishing chamber. During switching operations, the electric arc formed between contacts heats the chamber material, generating gas that rapidly cools and extinguishes the arc. This ensures safe interruption of load currents and minimizes contact wear.

Aplikasi

The VNA-10 load switches are commonly used in:

  • Indoor switchgear panels
  • Ring main units (RMU)
  • Compact transformer substations (KTP)
  • KSO and KRU cabinets
  • Industrial power distribution systems
  • Utility substations
  • Mining and infrastructure projects

Product Advantages

Reliable Arc Quenching

Auto-gas arc extinguishing technology provides stable and efficient load interruption.

Compact Structure

Ideal for installation inside medium voltage switchgear cabinets and compact substations.

Safe Operation

Mechanical interlocking prevents incorrect grounding and switching operations.

Long Service Life

Designed for high operational reliability with low maintenance requirements.

Optional Configurations

  • Left-side or right-side operating mechanism
  • Grounding blades on one or both sides
  • Fuse combination type
  • Polymer insulator version
  • Porcelain insulator version
  • Motorized operating mechanism