GW1 Interruptor de desconexión de alta tensión de 24 kV

GW1-24 high voltage disconnect switch is designed for 24kV outdoor AC distribution systems.

It provides reliable no-load isolation, visible disconnection, and safe operation for substations and overhead distribution networks.

Información complementaria

Detalles del producto:

The GW1-24 series outdoor disconnect switch adopts a double-column outdoor structure with three-phase linkage operation. It is suitable for outdoor installations in:

  • substations,
  • distribution lines,
  • transformer switching stations,
  • industrial power systems,
  • renewable energy distribution networks.

The switch is designed to:

  • isolate energized circuits without load current,
  • provide visible disconnection for maintenance,
  • improve operational safety,
  • support manual or motorized operation.

Optional versions include:

  • grounding switch type,
  • anti-pollution type,
  • motor-operated type,
  • porcelain or polymer insulator type.

Main Features

  • Rated voltage: 24kV
  • Outdoor installation type
  • Double-column opening structure
  • Visible isolation gap
  • Three-phase linkage operation
  • Manual or motorized operation
  • Optional grounding switch
  • Anti-pollution insulation design
  • Reliable mechanical interlocking
  • Long service life

Especificaciones técnicas

Artículo Especificación
Tensión nominal 24kV
Maximum Operating Voltage 27kV
Frecuencia nominal 50/60Hz
Corriente nominal 400A / 630A / 1000A / 1250A
Rated Short-Time Withstand Current 20kA / 25kA
Rated Peak Withstand Current 50kA / 63kA
Short-Circuit Duration 4s
Power Frequency Withstand Voltage 50kV / 60kV
Lightning Impulse Withstand Voltage 125kV / 145kV
Mechanical Life ≥2000 operations
Installation Type Outdoor

Modelo Significado

Typical models include:

  • GW1-24/400
  • GW1-24/630
  • GW1-24G/630-20
  • GW1-24(D)/1250-25

Meaning:

  • GW = Outdoor disconnect switch
  • 1 = Design serial number
  • 24 = Rated voltage (kV)
  • G = Improved anti-pollution type
  • D = With grounding switch
  • 400 / 630 / 1000 / 1250 = Rated current (A)
  • 20 / 25 = Short-time withstand current (kA)

Condiciones de trabajo

  • Ambient temperature: -40°C to +40°C
  • Altitude: ≤2000m or ≤3000m
  • Wind speed: ≤35m/s
  • Intensidad del terremoto: ≤8 grados
  • Ice thickness: ≤10mm
  • Suitable for polluted outdoor environments
  • Installation site should avoid:
    • explosive materials,
    • severe corrosion,
    • frequent violent vibration.

Aplicaciones

  • Outdoor substations
  • Overhead transmission lines
  • Pole-mounted distribution systems
  • Transformer isolation
  • Renewable energy substations
  • Industrial outdoor switchyards

Product Advantages

Reliable Outdoor Performance

Designed for stable operation under rain, UV, dust, and pollution conditions.

Visible Isolation

Provides clear visible disconnection for maintenance safety.

Flexible Operation

Supports manual CS8 operating mechanism or motorized drive systems.

Strong Mechanical Structure

Double-column design ensures reliable synchronization and long-term durability.

 

Esquema del dibujo

interruptor seccionador gw1 24kv

 

 

es_ARSpanish

Solicite un presupuesto rápido

Nos pondremos en contacto con usted en el plazo de 1 día laborable, por favor, preste atención al correo electrónico con el sufijo "@wolunele.com"