FN7-12/24 DR Interruptor-seccionador 12kV 24kV para interior (LBS)

FN7-12/24 DR indoor load break switch is designed for medium-voltage distribution systems up to 24kV.

It features compact structure, reliable load switching performance, optional fuse protection, and safe operation for switchgear and transformer applications.

Información complementaria

Detalles del producto:

The FN7-12/24 DR Indoor Load Break Switch (LBS) is a medium-voltage indoor switching device designed for 12kV and 24kV power distribution systems.

It is widely used in switchgear panels, RMU systems, substations, industrial plants, and transformer protection applications. The “DR” type generally refers to a load break switch combined with fuse protection.

Key Features

  • Rated voltage: 12kV / 24kV
  • Rated current: 400A / 630A
  • Frequency: 50/60Hz
  • Indoor installation type
  • Compact structure for switchgear cabinets
  • Reliable arc-extinguishing performance
  • Fuse combination available for transformer protection
  • Optional earthing switch
  • Mechanical interlock system for safety
  • IEC standard compliant (IEC 62271-105)

Main Applications

  • Medium voltage distribution panels
  • Ring Main Units (RMU)
  • Transformer feeder protection
  • Industrial substations
  • Commercial building power systems
  • Renewable energy distribution systems

Especificaciones técnicas

Artículo FN7-12DR FN7-24DR
Tensión nominal 12kV 24kV
Corriente nominal 400A / 630A 630A
Frecuencia nominal 50/60Hz 50/60Hz
Short-Circuit Making Current 31.5kA / 50kA 50kA
Short-Time Withstand Current 20kA 25kA
Lightning Impulse Withstand Voltage 75/85kV 125/145kV
Fuse Combination Breaking Capacity 1600A 900A
Mechanical Life 2000 operations 2000 operations

Modelo Significado

Typical model examples:

  • FN7-12DR/400-31.5
  • FN7-12DR/630-20
  • FN7-24DR/630

Meaning:

  • FN7 = Indoor AC high-voltage load break switch
  • 12 / 24 = Rated voltage
  • D = Earthing switch
  • R = Fuse combination
  • 400 / 630 = Rated current
  • 20 / 31.5 = Short-time withstand current (kA)

Product Advantages

Compact and Reliable

Suitable for compact switchgear designs and medium-voltage cabinets.

Fuse Protection Combination

The DR version works with current-limiting fuses to protect transformers against overload and short-circuit faults.

High Safety Performance

Interlocking structure prevents incorrect operation and improves operator safety.

Long Service Life

Mechanical endurance typically reaches 2000 operations.

Esquema y dibujo

 

ft

1. Cuchilla de extinción de arco 2. Pieza de contacto del arco y cámara de extinción del arco 3. Aislador Aislador 4. Base

5. Cuchilla de contacto dinámico 6. Cuchilla de contacto estático 7. Dispositivo de almacenamiento de energía del muelle (dentro del manguito del eje principal) 8. Brazo giratorio de la cuchilla principal

Dibujo 1 Esquema y tamaño de instalación del interruptor de carga FN7-12

 

fn7 24 interruptor-seccionador 24kv

 

1.Eje principal 2.Varilla aislante 3.Cuchilla 4.Contacto 5.Contacto de arco
6.Cámara de extinción del arco 7.Mecanismo de energía almacenada por muelle
8.Brazo de accionamiento On/Off

es_ARSpanish

Solicite un presupuesto rápido

Nos pondremos en contacto con usted en el plazo de 1 día laborable, por favor, preste atención al correo electrónico con el sufijo "@wolunele.com"