{"id":2310,"date":"2022-05-16T12:03:17","date_gmt":"2022-05-16T04:03:17","guid":{"rendered":"https:\/\/www.wolunelectric.com\/?post_type=product&#038;p=2310"},"modified":"2026-05-12T10:20:58","modified_gmt":"2026-05-12T02:20:58","slug":"rn2-high-voltage-fuse-for-generator-pt","status":"publish","type":"product","link":"https:\/\/www.wolunelectric.com\/ar\/product\/rn2-high-voltage-fuse-for-generator-pt\/","title":{"rendered":"\u0635\u0645\u0627\u0645\u0627\u062a \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0639\u0627\u0644\u064a RN2 \u0644\u0644\u0645\u0648\u0644\u062f\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 PT"},"content":{"rendered":"<h2>General Description<\/h2>\n<p>RN2 series indoor high voltage current limiting fuse is a professional protection component specially developed for Potential Transformer (PT) and generator loop protection in medium voltage power systems. It is widely applied in indoor high voltage switchgear, power distribution substations, industrial power plants, and generator control rooms, serving as reliable short-circuit and overload protection for voltage transformers and related high voltage auxiliary circuits.<\/p>\n<p>This fuse adopts high-strength ceramic outer tube, filled with high-purity quartz sand as arc-extinguishing medium, matched with precision melt inside. Under normal operating conditions, the fuse keeps stable conducting state with low power loss. When the circuit suffers short-circuit fault or abnormal overcurrent, the melt fuses instantly, and the quartz sand quickly absorbs arc energy to realize rapid arc extinction and current limiting, effectively isolating the faulty circuit and protecting PT equipment and the whole power system from damage.<br \/>\nMainly designed for indoor working environment, RN2 high voltage fuse supports multiple rated voltage levels including 3kV, 6kV, 10kV, 15kV, 20kV and 35kV. The standard rated current for PT protection is 0.5A, which perfectly matches the no-load and light-load working characteristics of potential transformers. It features accurate fusing characteristic, low overvoltage impact during breaking, high breaking capacity and stable electrical performance under long-term continuous operation.<\/p>\n<p>With compact integrated structure, rigorous manufacturing process and good mechanical vibration resistance, the RN2 fuse is easy to install, replace and maintain. It complies with IEC 60282 and GB\/T 15166.2 international and national standards, ensuring safe and reliable operation in various complex medium voltage power distribution occasions. It is the ideal dedicated protective fuse for generator PT, indoor high voltage cabinet, substation PT loop and industrial high voltage power distribution system.<\/p>\n<h2><strong>\u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629<\/strong><\/h2>\n<table width=\"577\">\n<tbody>\n<tr>\n<td width=\"240\">\u0627\u0644\u0637\u0631\u0627\u0632<\/td>\n<td colspan=\"3\" width=\"134\">RN2-3\u060c 6\u060c 10<\/td>\n<td colspan=\"2\" width=\"131\">RN2-15\u060c 20<\/td>\n<td width=\"72\">RN2-35<\/td>\n<\/tr>\n<tr>\n<td width=\"240\">\u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629<\/td>\n<td width=\"48\">3<\/td>\n<td width=\"38\">6<\/td>\n<td width=\"48\">10<\/td>\n<td width=\"60\">15<\/td>\n<td width=\"71\">20<\/td>\n<td width=\"72\">35<\/td>\n<\/tr>\n<tr>\n<td width=\"240\">\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646<\/td>\n<td colspan=\"3\" width=\"134\">0.5<\/td>\n<td colspan=\"2\" width=\"131\">0.5<\/td>\n<td width=\"72\">0.5<\/td>\n<\/tr>\n<tr>\n<td width=\"240\">\u0642\u062f\u0631\u0629 \u0643\u0633\u0631 \u062b\u0644\u0627\u062b\u064a\u0629 \u0627\u0644\u0637\u0648\u0631<\/td>\n<td colspan=\"6\" width=\"337\">1000<\/td>\n<\/tr>\n<tr>\n<td width=\"240\">\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649. \u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0633\u0631 (\u0627\u0644\u0642\u064a\u0645\u0629 \u0627\u0644\u0641\u0639\u0627\u0644\u0629)<\/td>\n<td width=\"48\">100<\/td>\n<td width=\"38\">85<\/td>\n<td width=\"48\">50<\/td>\n<td width=\"60\">40<\/td>\n<td width=\"71\">30<\/td>\n<td width=\"72\">17<\/td>\n<\/tr>\n<tr>\n<td width=\"240\">\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649 \u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0630\u0631\u0648\u0629 \u0639\u0646\u062f \u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649 \u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 \u0627\u0644\u0645\u0642\u0637\u0648\u0639\u0629<\/td>\n<td width=\"48\">160<\/td>\n<td width=\"38\">300<\/td>\n<td width=\"48\">1000<\/td>\n<td width=\"60\">350<\/td>\n<td width=\"71\">850<\/td>\n<td width=\"72\">700<\/td>\n<\/tr>\n<tr>\n<td width=\"240\">\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0632\u0627\u0626\u062f<\/td>\n<td colspan=\"6\" width=\"337\">\u0644\u064a\u0633 \u0623\u0643\u062b\u0631 \u0645\u0646 2.5 \u0645\u0631\u0629 \u0645\u0646 \u062c\u0647\u062f \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/td>\n<\/tr>\n<tr>\n<td width=\"240\">\u0645\u0642\u0627\u0648\u0645\u0629 \u0627\u0644\u0623\u0646\u0627\u0628\u064a\u0628 \u0627\u0644\u0630\u0627\u0626\u0628\u0629<\/td>\n<td colspan=\"3\" width=\"134\">100\u00b17<\/td>\n<td colspan=\"2\" width=\"131\">200\u00b110<\/td>\n<td width=\"72\">380\u00b110<\/td>\n<\/tr>\n<tr>\n<td width=\"240\">\u0627\u0644\u0648\u0632\u0646<\/td>\n<td colspan=\"3\" width=\"134\">5.6<\/td>\n<td colspan=\"2\" width=\"131\">12<\/td>\n<td width=\"72\">15.6<\/td>\n<\/tr>\n<tr>\n<td width=\"240\">\u0648\u0632\u0646 \u0627\u0644\u0623\u0646\u0628\u0648\u0628 \u0627\u0644\u0630\u0627\u0626\u0628<\/td>\n<td colspan=\"3\" width=\"134\">0.9<\/td>\n<td colspan=\"2\" width=\"131\">1.6<\/td>\n<td width=\"72\">2.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>Key Specifications<\/h2>\n<ul>\n<li><strong>\u0627\u0644\u0637\u0631\u0627\u0632<\/strong>: RN2<\/li>\n<li><strong>\u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629<\/strong>: 3kV \/ 6kV \/ 10kV \/ 15kV \/ 20kV \/ 35kV<\/li>\n<li><strong>\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646<\/strong>: 0.5A (standard for PT protection)<\/li>\n<li><strong>\u0627\u0644\u062a\u0631\u062f\u062f \u0627\u0644\u0645\u0642\u062f\u0631<\/strong>: 50Hz \/ 60Hz<\/li>\n<li><strong>Breaking Capacity (Three-phase)<\/strong>: Up to 1000 MVA<\/li>\n<li><strong>Max Breaking Current (rms)<\/strong>:\n<ul>\n<li>3kV: 100kA<\/li>\n<li>6kV: 85kA<\/li>\n<li>10kV: 50kA<\/li>\n<li>15kV: 40kA<\/li>\n<li>20kV: 30kA<\/li>\n<li>35kV: 17kA<\/li>\n<\/ul>\n<div><\/div>\n<\/li>\n<li><strong>Fusing Characteristic<\/strong>: 0.6\u20131.8A fusing current within 1 minute<\/li>\n<li><strong>Overvoltage Limitation<\/strong>: \u22642.5\u00d7 rated voltage<\/li>\n<li><strong>Installation<\/strong>: Indoor, for PT primary side protection<\/li>\n<li><strong>Material<\/strong>: Ceramic tube with quartz sand filler<\/li>\n<li><strong>Standard<\/strong>: IEC 60282, GB\/T 15166.2<\/li>\n<\/ul>\n<h2>Main Features<\/h2>\n<p>\u2022 \u2705 PT &amp; Generator Dedicated: Specifically for potential transformer (PT) and generator protection<br \/>\n\u2022 \u2705 Current Limiting: Fast-acting, limits short-circuit current before peak<br \/>\n\u2022 \u2705 High Reliability: Stable performance in indoor MV switchgear<br \/>\n\u2022 \u2705 Compact &amp; Easy Mounting: Simple structure, easy installation and replacement<\/p>\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h2>\n<p>\u2022 Generator voltage transformers (PT)<br \/>\n\u2022 Indoor MV switchgear (3\u201335kV)<br \/>\n\u2022 Power distribution substations<br \/>\n\u2022 Industrial plant PT circuits<\/p>\n<h2><strong>\u0623\u0628\u0639\u0627\u062f \u0627\u0644\u0645\u062e\u0637\u0637 \u0627\u0644\u062a\u0641\u0635\u064a\u0644\u064a\u00a0<\/strong><\/h2>\n<h3>\u0623\u0628\u0639\u0627\u062f \u0627\u0644\u0645\u062e\u0637\u0637 \u0627\u0644\u062a\u0641\u0635\u064a\u0644\u064a \u0644\u0644\u0637\u0631\u0627\u0632 RN2-3\u060c 6\u060c 10\/0.5<\/h3>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-medium wp-image-2312\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2022\/05\/RN2-fuse-dimension-1-300x240.png\" alt=\"\u0628\u064f\u0639\u062f \u0627\u0644\u0645\u0635\u0647\u0631 rn2 1\" width=\"300\" height=\"240\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2022\/05\/RN2-fuse-dimension-1-300x240.png 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2022\/05\/RN2-fuse-dimension-1.png 367w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h3>\u0623\u0628\u0639\u0627\u062f \u0627\u0644\u0645\u062e\u0637\u0637 \u0627\u0644\u062a\u0641\u0635\u064a\u0644\u064a \u0644\u0644\u0637\u0631\u0627\u0632 RN2-15\u060c 20\/2-0.5<\/h3>\n<p><img decoding=\"async\" class=\"alignnone size-medium wp-image-2313\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2022\/05\/RN2-fuse-dimension-2-300x255.png\" alt=\"\u0627\u0644\u0628\u064f\u0639\u062f 2 \u0641\u064a\u0648\u0632 2\" width=\"300\" height=\"255\" srcset=\"https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2022\/05\/RN2-fuse-dimension-2-300x255.png 300w, https:\/\/www.wolunelectric.com\/wp-content\/uploads\/2022\/05\/RN2-fuse-dimension-2.png 329w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<h3>\u0623\u0628\u0639\u0627\u062f \u0627\u0644\u0645\u062e\u0637\u0637 \u0627\u0644\u062a\u0641\u0635\u064a\u0644\u064a \u0644\u0644\u0637\u0631\u0627\u0632 RN2-35\/0.5<\/h3>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-2314\" src=\"http:\/\/www.wolunelectric.com\/wp-content\/uploads\/2022\/05\/RN2-fuse-dimension-3.png\" alt=\"\u0627\u0644\u0628\u064f\u0639\u062f 3 \u0635\u0645\u0627\u0645\u0627\u062a rn2 \u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a 3\" width=\"295\" height=\"268\" \/><\/p>","protected":false},"excerpt":{"rendered":"<h4><strong>\u0635\u0645\u0627\u0645 \u0645\u062d\u0648\u0644 \u0627\u0644\u062c\u0647\u062f RN2<\/strong><\/h4>","protected":false},"featured_media":2315,"template":"","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"RN2 High Voltage Current Limiting Fuse for Generator & Potential Transformer (PT) Protection","_seopress_titles_desc":"RN2 series indoor high voltage current limiting fuse is designed for short-circuit and overload protection of generator voltage transformers (PT) in 3kV\u201335kV systems, featuring high breaking capacity and stable performance.","_seopress_robots_index":""},"product_brand":[],"product_cat":[47],"product_tag":[],"class_list":{"0":"post-2310","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-fuse-tube","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.wolunelectric.com\/ar\/wp-json\/wp\/v2\/product\/2310","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.wolunelectric.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.wolunelectric.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ar\/wp-json\/wp\/v2\/media\/2315"}],"wp:attachment":[{"href":"https:\/\/www.wolunelectric.com\/ar\/wp-json\/wp\/v2\/media?parent=2310"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ar\/wp-json\/wp\/v2\/product_brand?post=2310"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ar\/wp-json\/wp\/v2\/product_cat?post=2310"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.wolunelectric.com\/ar\/wp-json\/wp\/v2\/product_tag?post=2310"}],"curies":[{"name":"\u062f\u0628\u0644\u064a\u0648 \u0628\u064a","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}